Journal of Radiation Research and Radiation Processing, Volume. 43, Issue 3, 030501-1(2025)

Uncertainty evaluation of the measurement of gross beta activity in the groundwater of a nuclear power plant

Juntao ZHENG1, Di WU2, Jin XU3, Guopeng XU3, Zhihao ZHENG4, and Feng CHENG1、*
Author Affiliations
  • 1Yangjiang Nuclear Power Co., Ltd., Yangjiang, Yangjiang 529941, China
  • 2Daya Bay Nuclear Power Operations and Management Co. Ltd., Shenzhen 518124, China
  • 3CGN Huizhou Nuclear Power Co., Ltd., Huizhou 516353, China
  • 4Huizhou Ruihui Labor Property Management Co., Ltd., Huizhou 516005, China
  • show less
    Figures & Tables(3)
    Causal relationship of uncertainty component of gross beta activity measurement in groundwater
    • Table 1. Independent measurement results of gross beta activity sampling

      View table
      View in Article

      Table 1. Independent measurement results of gross beta activity sampling

      No.Cβ/(Bq·L-1)No.Cβ/(Bq·L-1)
      Cβ¯  /(Bq·L-1)=0.818
      10.81270.821
      20.79580.791
      30.82090.782
      40.798100.864
      50.834110.832
      60.841120.829
    • Table 2. Summary table of each uncertainty component

      View table
      View in Article

      Table 2. Summary table of each uncertainty component

      序号

      No.

      不确定度分量

      Uncertainty component

      相对标准不确定度 / % Relative standard uncertainty
      1抽样引入的不确定度urel(S) Uncertainty introduced by sampling urel(S)2.91
      2样品测量计数引入的不确定度urel(R) Uncertainty introduced by sample counting rate urel(R)2.66
      3

      标准物质净计数率引入的不确定度urel(Rs0)

      Uncertainty introduced by net count rate of standard material urel(Rs0)

      1.34
      4

      标准物质比活度引入的不确定度urel(βs)

      Uncertainty introduced by specific activity of standard material urel(βs)

      2.75
      5样品取样量引入的不确定度urel(V) Uncertainty introduced by the amount of sample taken urel(V)0.46
      6残渣总质量引入的不确定度urel(M) Uncertainty introduced by total mass of residue urel(M)0.06
      7

      体积校正系数1.02引入的不确定度urel(1.02)

      Uncertainty introduced by volume correction coefficient 1.02 urel(1.02)

      0.06
      8样品回收率引入的不确定度urel(F) Uncertainty introduced by sample recovery rate urel(F)3.33
      9

      铺样均匀性引入的不确定度urel(fPaving sample)

      Uncertainty introduced by sample uniformity urel(fPaving sample)

      2.24
      10

      α射线对β道串道比引入的不确定度urel(fCrosstalk ratio)

      Uncertainty introduced by crosstalk ratio of α-ray cross-talk in the β channel urel(fCrosstalk ratio)

      5.77
      11数据修约引入的不确定度urel(βData rounding) Uncertainty introduced by data rounding urel(βData rounding)0.04
    Tools

    Get Citation

    Copy Citation Text

    Juntao ZHENG, Di WU, Jin XU, Guopeng XU, Zhihao ZHENG, Feng CHENG. Uncertainty evaluation of the measurement of gross beta activity in the groundwater of a nuclear power plant[J]. Journal of Radiation Research and Radiation Processing, 2025, 43(3): 030501-1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: RADIATION DOSIMETRY

    Received: Sep. 24, 2024

    Accepted: Nov. 23, 2024

    Published Online: Jul. 7, 2025

    The Author Email: Feng CHENG (成丰)

    DOI:10.11889/j.1000-3436.2024-0079

    Topics