Acta Optica Sinica, Volume. 41, Issue 24, 2408002(2021)

Influence of Collimator Divergence Angle on Geometric Calibration Accuracy of Directional Polarimetric Camera and its correction method

Guangfeng Xiang1,2,3、**, Binghuan Meng1,3、*, Chan Huang1,2,3, Shuang Li1,3, Sunlong Xu1,3, Yang Li1,2,3, Lin Han1,3, Liang Sun1,3, Donggen Luo1,3, and Jin Hong1,3、***
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2University of Science and Technology of China, Hefei, Anhui 230026, China
  • 3Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • show less
    Figures & Tables(12)
    Optical system structure of DPC
    Distortion characteristic of DPC
    Geometric model of DPC
    Laboratory geometric calibration device of DPC
    Object-image relationship of collimator
    Positioning error of image point (regardless of distortion)
    Positioning error of image point (considering distortion, divergence angle α=2°)
    Spot distribution diagram of geometric calibration test
    Fitting residual contrast of 670-nm band. (a) X direction; (b) Y direction; (c) Euclidean distance
    Image point position deviation calculated by geometric model
    • Table 1. Basic parameters of DPC

      View table

      Table 1. Basic parameters of DPC

      ParameterGF-5GF-5(02)CMDQ-1
      Focal length /mm4.85.544.85.54
      FOV /(°)Cross track±50±50±50±50
      Along track±50±50±40±50
      Relative aperture1∶41∶4.261∶41∶4.26
      CCD array size512×5121024×1024360×5121024×1024
      Pixel size /μm22.5×22.513×1322.5×22.513×13
      Band /nmPolarized490(20)、670(20)、865(40)
      Non-polarized443(20)、565(20)、763(10)、765(40)、910(20)
    • Table 2. Geometric model parameters of DPC

      View table

      Table 2. Geometric model parameters of DPC

      Band /nmOriginal methodProposed method
      XkSYkSf1kf3kf5kXkSYkSf1kf3kf5k
      443200.79255.79216.262.01-1.45200.79255.79216.201.90-1.41
      490200.81255.83215.852.47-1.65200.81255.83215.802.35-1.60
      565200.75255.82215.523.03-1.89200.75255.82215.462.93-1.86
      670200.78255.84215.323.54-2.12200.78255.84215.273.45-2.10
      763200.73256.80215.253.83-2.25200.72256.80215.203.74-2.22
      765200.78255.79215.243.84-2.25200.78255.79215.193.75-2.22
      865200.80255.81215.174.10-2.36200.79255.81215.123.99-2.33
      910200.82255.80215.164.16-2.39200.82255.80215.114.07-2.36
    Tools

    Get Citation

    Copy Citation Text

    Guangfeng Xiang, Binghuan Meng, Chan Huang, Shuang Li, Sunlong Xu, Yang Li, Lin Han, Liang Sun, Donggen Luo, Jin Hong. Influence of Collimator Divergence Angle on Geometric Calibration Accuracy of Directional Polarimetric Camera and its correction method[J]. Acta Optica Sinica, 2021, 41(24): 2408002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Geometric Optics

    Received: May. 10, 2021

    Accepted: Jun. 22, 2021

    Published Online: Nov. 30, 2021

    The Author Email: Xiang Guangfeng (xgf056@mail.ustc.edu.cn), Meng Binghuan (bhmeng@aiofm.ac.cn), Hong Jin (hongjin@aiofm.ac.cn)

    DOI:10.3788/AOS202141.2408002

    Topics