Laser & Optoelectronics Progress, Volume. 60, Issue 11, 1106033(2023)

Roof Separation Sensor Based on Fiber Bragg Grating

Zegong Wu1, Lu Cao2, Yanong Ning2, Qingshan Yang2, and Tongyu Liu1,2、*
Author Affiliations
  • 1Laser Institute, Shandong Academy of Sciences, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250104, Shandong, China
  • 2Shandong Micro-Sensor Photonics Ltd., Jinan 250103, Shandong, China
  • show less
    Figures & Tables(8)
    Simplified diagram of the internal objects for roof separation sensor
    Interior physical drawings for roof separation sensor
    Schematic diagram of the experimental setup
    Temperature and wavelength diagram
    Wavelength and standard displacement diagram
    • Table 1. Error analysis at 40 ℃

      View table

      Table 1. Error analysis at 40 ℃

      Standard /mmTemperature FBG /nmStrain FBG /nmDemodulation /mmError /mm
      0.001567.0221549.4770.0000.000
      30.001567.0211549.57830.4760.476
      60.001567.0221549.67859.299-0.701
      90.001567.0221549.78189.686-0.314
      120.001567.0221549.883119.778-0.222
      150.001567.0211549.985150.5490.549
      180.001567.0221550.087179.962-0.038
      210.001567.0221550.189210.0540.054
      240.001567.0221550.291240.1460.146
      270.001567.0221550.393270.2380.238
      300.001567.0221550.495300.3300.330
    • Table 2. Error analysis at 27 ℃

      View table

      Table 2. Error analysis at 27 ℃

      Standard /mmTemperature FBG /nmStrain FBG /nmDemodulation /mmError /mm
      0.001566.8901549.3330.0000.000
      30.001566.8901549.44031.5671.567
      60.001566.8911549.54060.3820.382
      90.001566.8911549.63788.999-1.001
      120.001566.8911549.745125.8760.876
      150.001566.8911549.847155.9680.968
      180.001566.8911549.949181.0451.045
      210.001566.8911550.051211.1371.137
      240.001566.8911550.153241.2291.229
      270.001566.8911550.255271.3211.321
      300.001566.8891550.342298.363-1.637
    • Table 3. Error analysis at 0 ℃

      View table

      Table 3. Error analysis at 0 ℃

      Standard /mmTemperature FBG /nmStrain FBG /nmDemodulation /mmError /mm
      0.001566.6161548.9490.0000.000
      30.001566.6161549.04929.5020.498
      60.001566.6151549.14658.7971.203
      90.001566.6161549.25289.3910.609
      120.001566.6161549.353119.1880.812
      150.001566.6161549.458150.165-0.165
      180.001566.6161549.558179.6670.333
      210.001566.6161549.660209.7590.241
      240.001566.6161549.761239.5560.444
      270.001566.6161549.868271.123-1.123
      300.001566.6161549.969300.920-0.920
    Tools

    Get Citation

    Copy Citation Text

    Zegong Wu, Lu Cao, Yanong Ning, Qingshan Yang, Tongyu Liu. Roof Separation Sensor Based on Fiber Bragg Grating[J]. Laser & Optoelectronics Progress, 2023, 60(11): 1106033