Chinese Journal of Lasers, Volume. 41, Issue 7, 704002(2014)

Correlation Analysis and Calibration of Noninvasive Blood Glucose Monitoring in vivo with Optical Coherence Tomography

Su Ya1、*, Meng Zhuo1,2, Wang Longzhi1, Yu Haimin2,3, Liu Tiegen1, and Yao Xiaotian1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(11)

    [1] [1] Wang Zhen, Zhang Hong, Shen Xuhui, et al.. The study on the risk factors for pre-diabetes and diabetes[J]. Chinese J Diabetes, 2012,20(6): 421-423.

    [3] [3] Chong Bo, Zhu Yongkai. Method to improve axial resolution of spectral domain optical coherence tomography[J]. Acta Optica Sinica, 2013,33(2): 0217001.

    [4] [4] Rinat O Esenaliev, Krill V Larin, Irina V Larina, et al.. Non-invasive monitoring of glucose concentration with optical coherence tomography[J]. Opt Lett, 2001, 26(13): 992-994.

    [5] [5] Robert A Gabbay, Surendra Sivarajah. Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes[J]. Diabetes Technology & Therapeutics. 2008, 10(3): 188-193.

    [6] [6] Nan Nan, Bu Peng, Guo Xin, et al.. Three-dimensional full-range complex Fourier domain optical coherence tomography system for vivo imaging of human skin[J]. Chinese J Lasers, 2012, 39(7): 0704002.

    [7] [7] Yasuaki Hori, Yoshiaki Yasuno. Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography[J]. Opt Express, 2006, 14(5): 1862-1877.

    [8] [8] A Bhandari, B Hamre,  Frette, et al.. Modeling optical properties of human skin using Mie theory for particles with different size distributions and refractive indices[J]. Opt Express, 2011, 19(15): 14549-14567.

    [9] [9] R Poddar, S R Sharma, J T Andrews, et al.. Correlation between glucose concentration and reduced scattering coefficients in turbid media using optical coherence tomography[J]. Current Science, 2008, 95(3): 340-344.

    [10] [10] Veronika V Sapozhnikova, Roman V Kuranov, Inga Cicenaite, et al.. Effect on blood glucose monitoring of skin pressure exerted by an optical coherence tomography probe[J]. J Biomedical Opt, 2008, 13(2): 021112,

    [11] [11] Mohamad G Ghosn, Narendran Sudheendran, Mark Wendt, et al.. Monitoring of glucose permeability in monkey skin in vivo using optical coherence tomography[J]. J Biophotonics, 2010, 3(1-2): 25-33.

    CLP Journals

    [1] Yang Fan, fanGao Wanrong, Zhu Yue. Hilbert Transform in Full-Field Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2016, 53(11): 111102

    [2] Zhang Yuanzhi, Pan Liang, Wang Yikun, Hou Huayi, Zhu Ling, Wang An, Liu Yong. Calibration for Tissue Fluorescence Spectroscopy System[J]. Laser & Optoelectronics Progress, 2015, 52(8): 81701

    [3] Wang Jiao, Liu Rong, Yu Xuyao, Han Guang, Xu Kexin. Research on Existence of Floating Reference Position in Human Body[J]. Acta Optica Sinica, 2016, 36(6): 630003

    [4] Liu Hao, Gao Wanrong, Chen Chaoliang. Handheld Spectral Domain Optical Coherence Tomography for in vivo Tooth Imaging[J]. Chinese Journal of Lasers, 2016, 43(2): 204003

    [5] Shi Weisong, Gao Wanrong, Chen Chaoliang. Handheld Swept Source Optical Coherence Tomography for Imaging Human Skin in vivo[J]. Acta Optica Sinica, 2015, 35(11): 1117001

    [6] Wang Ling, Tu Pei, Shi Ran, Xu Ming′en. Quantitative Evaluation of Three-Dimensional Bio-Printed Hydrogel Scaffolds by Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2015, 42(8): 804003

    [7] Ren Zhong, Liu Guodong, Huang Zhen. Study on Photoacoustic Noninvasive Detection for Blood Glucose Concentration Based on Tunable Pulsed Laser[J]. Chinese Journal of Lasers, 2016, 43(2): 204001

    [8] Qin Yuwei. Study on Defect Detection of Optical Thin Film Using Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2015, 52(7): 71202

    [9] Yu Zhenfang, Qiu Qi, Guo Yong. Dual Modulation Optical Polarimetry for Glucose Monitoring[J]. Acta Optica Sinica, 2016, 36(1): 117001

    [10] Yu Zhenfang, Qiu Qi, Zhang Tianhang, Guo Yong. Dual-Modulation Multi-Wavelength Polarimetry for Monitoring Glucose Concentration in Anterior Chamber of Eye Phantoms[J]. Acta Optica Sinica, 2016, 36(11): 1117003

    [11] Hu Zhixiong, Hao Bingtao, Liu Wenli, Hong Baoyu. Research on Point Spread Function Phantom Fabrication and Application for Evaluating Resolution Performance of OCT Systems[J]. Acta Optica Sinica, 2015, 35(4): 417001

    Tools

    Get Citation

    Copy Citation Text

    Su Ya, Meng Zhuo, Wang Longzhi, Yu Haimin, Liu Tiegen, Yao Xiaotian. Correlation Analysis and Calibration of Noninvasive Blood Glucose Monitoring in vivo with Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2014, 41(7): 704002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 24, 2014

    Accepted: --

    Published Online: Jun. 24, 2014

    The Author Email: Ya Su (suya1@sina.com)

    DOI:10.3788/cjl201441.0704002

    Topics