High Power Laser and Particle Beams, Volume. 35, Issue 2, 024004(2023)

Development of an H0CT measurement system at the CSNS injection region

Ruiyang Qiu1,2, Weiling Huang1,2、*, Lei Zeng1,2, Zhihong Xu1,2, Fang Li1,2, Ming Meng1,2, Tao Yang1,2, Anxin Wang1,2, Mengyu Liu3, Jilei Sun1,2, and Taoguang Xu2
Author Affiliations
  • 1Spallation Neutron Source Science Center, Dongguan 523803, China
  • 2Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(14)
    Layout of CSNS injection region[11]
    External core to measure environmental noise
    Interference signal output by the electronics
    H0CT sensors and magnetic shieldings[12]
    Electronics block diagram
    The electronics output with 10 μA calibrated input
    H0CT-BCT electronics calibration data
    Minimal noise triax cable grounding diagram
    Electrical output diagram for different grounding modes
    H0 measured by H0CT at different H− beam current
    Comparison chart of H0CT and fluorescent target
    • Table 1. Comparison of stripping methods and beam parameters of similar accelerators in the world

      View table
      View in Article

      Table 1. Comparison of stripping methods and beam parameters of similar accelerators in the world

      facilitypulse widthbeam intensity/mAbeam instrumentsstripping methodstripping efficiency
      ISIS-RCS[3]200 - 250 µs40BCT1. Al2O3 Foil 2. diamond like carbon foil (DLC) 98%±1%(estimated) 99% (simulated)
      CERN-PSB[4-5]400 µs(1.2 ms)40/20BCT BCT+H0/H monitor 1. graphite foil 2. carbon based foil 99%
      SNS[6-8]1 ms38BCM(FCT)1. diamond foil 2. laser assisted Lorentz stripping 99%(maximum)
      J-PARC[9]600 µs50BCT+preamplifier1. carbon foil 2. hybrid-type boron doped carbon foil 99.7%
    • Table 2. Optimized electronics parameters

      View table
      View in Article

      Table 2. Optimized electronics parameters

      frequency/Hzmacro pulse width/μsturns of torus/ turndroop/(%/ms)risetime/μsmeasuring range/μA
      2550 – 50050< 1< 10±50
    • Table 3. Cable noise measurement

      View table
      View in Article

      Table 3. Cable noise measurement

      cabletriaxcable quad
      CT-output (single-end earthed)/mV 206286
      CT-output (double-end earthed)/mV 54166
    Tools

    Get Citation

    Copy Citation Text

    Ruiyang Qiu, Weiling Huang, Lei Zeng, Zhihong Xu, Fang Li, Ming Meng, Tao Yang, Anxin Wang, Mengyu Liu, Jilei Sun, Taoguang Xu. Development of an H0CT measurement system at the CSNS injection region[J]. High Power Laser and Particle Beams, 2023, 35(2): 024004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Particle Beams and Accelerator Technology

    Received: May. 6, 2022

    Accepted: Oct. 11, 2022

    Published Online: Feb. 16, 2023

    The Author Email: Huang Weiling (huangwei@ihep.ac.cn)

    DOI:10.11884/HPLPB202335.220142

    Topics