NUCLEAR TECHNIQUES, Volume. 46, Issue 1, 010402(2023)

Design of NNBI RF power source output power control system

Zhao WANG1, Mingwei WANG1、*, Tao LEI1, Jianjun BAI2, and Rui GE2
Author Affiliations
  • 1School of Electronic Information and Artificial Intelligence, Shaanxi University of Science & Technology, Xi'an 710021, China
  • 2Shaanxi Xuntian Broadcast Technology Co., Ltd., Xianyang 712000, China
  • show less
    Figures & Tables(10)
    Block diagram of power control system design
    Schematic of power synthesis
    Block diagram of power closed-loop control logic
    Block diagram of power closed-loop control strategy
    Structure diagram of output power sampling circuit
    Photo of core control board
    Photo of multistage RF power amplifier module
    • Table 1. Correspondence between binary data B6~B1 and standard power amplifier module

      View table
      View in Article

      Table 1. Correspondence between binary data B6~B1 and standard power amplifier module

      B1-B2-B3-B4-B5-B6

      对应导通的模块

      Corresponding conduction module

      导通的总模块数

      Total number of modules conducted

      0-0-0-0-0-0None0
      0-0-0-0-0-111
      0-0-0-0-1-01~22
      0-0-0-0-1-11~33
      ………………
      1-1-1-1-0-01~6060
      1-1-1-1-0-11~6060
    • Table 2. Digital power control test results

      View table
      View in Article

      Table 2. Digital power control test results

      功率设置值

      Power setting value / kW

      数字化控制字

      Digitized control word

      开通功放模块数量(标准模块+微调模块)

      Number of power amplifier modules turned on (standard module + fine tuning module)

      实测输出功率

      Measured output power / kW

      0.000X0000+00
      20.000X50020+020.01
      20.010X50120+120.02
      20.030X50220+120.04
      20.040X50320+220.05
      35.000X8C035+035.03
      50.000XC8050+050.02
      60.000XF0060+060.04
    • Table 3. Closed loop power control test results

      View table
      View in Article

      Table 3. Closed loop power control test results

      功率设置值

      Power setting value / kW

      反射功率值

      Reflected power value / kW

      自动追加开通功放模块数(标准模块+微调模块)

      Add the number of automatic power amplifier modules (standard module + fine tuning module)

      实测输出功率

      Measured output power / kW

      功率误差

      Power error / kW

      10.000.600+210.010.01
      20.001.501+220.040.04
      35.002.902+535.090.09
      50.005.205+350.120.12
    Tools

    Get Citation

    Copy Citation Text

    Zhao WANG, Mingwei WANG, Tao LEI, Jianjun BAI, Rui GE. Design of NNBI RF power source output power control system[J]. NUCLEAR TECHNIQUES, 2023, 46(1): 010402

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Jun. 21, 2022

    Accepted: --

    Published Online: Feb. 17, 2023

    The Author Email: WANG Mingwei (wangmingwei@sust.edu.cn)

    DOI:10.11889/j.0253-3219.2023.hjs.46.010402

    Topics