Acta Photonica Sinica, Volume. 53, Issue 3, 0312003(2024)

Invention Relates to an Automatic Coordinate System Calibration Method Applied to a Large Size Measurement System

Xiaohui ZHANG, Jiaying ZHANG, Qing LIU*, Jintong LI, Qihang YANG, Jiaming LV, Ting SHANG, and Pengfei CHENG
Author Affiliations
  • School of Automation and Information Engineering, Xi'an University of Technology, Xi'an 710048, China
  • show less
    Figures & Tables(17)
    Schematic diagram of measurement units measuring each other
    The composition of the ALPS system
    Two-station intersection measurement diagram
    Schematic for calibrating the mark targets
    Initial value solution diagram
    Schematic diagram of mutual scan measurement at transmitter station
    Experimental scene
    Comparison diagram of length measurement error compared with standard method
    Comparison diagram of LM optimization method and Gaussian Newton optimization method
    Illustration of the target ball
    Test point distribution map
    Repeat point standard deviation
    Measurement error compared with laser tracker
    Self-calibration method using inter-scanning technique and ultrasonic ranging
    • Table 1. Internal parameters of laser transmitters

      View table
      View in Article

      Table 1. Internal parameters of laser transmitters

      TransmitterPlaneABCD
      110.017 681 453-0.428 387 511-0.736 372 8760.000 000 000
      20.964 419 2280.010 089 585-0.520 140 0080.000 000 000
      21-0.331 011 200-0.800 227 994-0.432 092 8640.000 000 000
      20.758 123 749-0.309 036 328-0.542 004 9910.000 000 000
    • Table 2. Scan the target coordinates at the laser transmitters

      View table
      View in Article

      Table 2. Scan the target coordinates at the laser transmitters

      X/mmY/mmZ/mm
      Q111886.656 456 465 5980.256 453 156 5210.657 852 232 12
      Q1126.541 154 515 152801.325 645 154 5928.514 145 145 141
      Q2212.064 151 545 125817.125 461 256 4516.456 541 514 554
      Q222869.456 415 415 4542.415 615 445 14529.564 584 545 154
    • Table 3. Comparison of the standard ruler method and the method in this paper

      View table
      View in Article

      Table 3. Comparison of the standard ruler method and the method in this paper

      Standard ruler methodProposed method
      Calibration procedureAfter the transmitters are secured, the standard ruler is placed in at least 6 positions, each of which needs to maintain a vertical attitudeAfter fixing the transmitters, the transmitters are automatically calibrated by scanning each other's mark targets
      Time-consumingAbout 50 minAbout 5 min

      Ways to add

      transmitters

      Re-calibrationAutomatic Networking Mechanism
      Average ranging accuracyWithin 0.2 mm/mWithin 0.46 mm/m
    Tools

    Get Citation

    Copy Citation Text

    Xiaohui ZHANG, Jiaying ZHANG, Qing LIU, Jintong LI, Qihang YANG, Jiaming LV, Ting SHANG, Pengfei CHENG. Invention Relates to an Automatic Coordinate System Calibration Method Applied to a Large Size Measurement System[J]. Acta Photonica Sinica, 2024, 53(3): 0312003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Aug. 21, 2023

    Accepted: Oct. 16, 2023

    Published Online: May. 16, 2024

    The Author Email: Qing LIU (itcliuq@xaut.edu.cn)

    DOI:10.3788/gzxb20245303.0312003

    Topics