Acta Optica Sinica, Volume. 29, Issue 10, 2780(2009)

Analysis of Three-Dimensional Measurement System and the Coordinates Calibration in Fourier Transform Profilometry

Wu Shuangqing*, Zhang Yin, Zhang Sanyuan, and Ye Xiuzi
Author Affiliations
  • [in Chinese]
  • show less
    References(18)

    [1] [1] Frank Chen,Gordon M.Brown,Mumin Song. Overview of three-dimensional shape measurement using optical methods [J]. Optical Engineering,2000,39(1):10-22

    [2] [2] Peisen S. Huang,Chengping Zhang,Fupen Chiang. High-speed 3-D shape measurement based on digital fringe projection [J]. Optical Engineering,2002,42(1):163-168

    [3] [3] Song Zhang,Shingtung Yau. Three-dimensional shape measurement using a structured light system with dual cameras [J]. Optical Engineering,2008,47(1):013604

    [4] [4] M. Takeda,K. Mutoh. Fourier transform profilometry for the automatic measurement of 3-D object shape [J]. Applied Optics,1983,22(24):3977-3982

    [5] [5] X. Su,W. Chen. Fourier transform profilometry:a review [J]. Optics and Lasers in Engineering,2001,35(5):263-284

    [6] [6] Koichi Iwata,Fuminori Kusunoki,Kousuke Moriwaki et al.. Three-dimensional profiling using the Fourier transform method with a hexagonal grating projection [J]. Applied Optics,2008,47(20):2103-2108

    [7] [7] Qingying Hu,Huang Peisen,Fu Qionglin et al.. Calibration of a three-dimensional shape measurement system[J]. Optical Engineering,2003,42(2):487-493

    [9] [9] Xu Guangyou,Liu Lifeng,Zeng Jianchao et al.. A new method of calibration in 3D vision system based on structure-light [J]. Chinese J. Computers,1995,18(6):450-456

    [10] [10] Anand Asundi,Zhou Wensen. Unified calibration technique and its applications in optical triangular profilometry [J]. Appl. Opt.,1999,38(16):3556-3561

    [12] [12] S. Zhang,P. S. Huang. Novel method for structured light system calibration [J]. Optical Engineering,2006,45(8):083601

    [13] [13] Yong Li,Xianyu Su,Qingyang Wu. Accurate phase-height mapping algorithm for PMP[J]. J. Modern Optics,2006,53(14):1955-1964

    [17] [17] Zhang Zhengyou. A flexible new technique for camera calibration [J]. IEEE Transactions on Pattern Analysis and Machine Intelligence,2000,22(11):1330-1334

    [18] [18] Y. Yongtae. A piecewise hole filling algorithm in reverse engineering [J]. Computer-Aided Design,2005,37(2):263-270

    CLP Journals

    [1] Yuan Yuwei, Quan Jicheng, Wu Chen, Liu Yu, Wang Hongwei. Ray Tracing Acceleration Structure Based on Octree Adaptive Volume Merging[J]. Acta Optica Sinica, 2017, 37(1): 120001

    [2] He Yuhang, Cao Yiping, Zhai Aiping. A 3-D Measurement Method with Orthogonal Composite Light Based on Fringe Contrast and Background Calibration[J]. Acta Optica Sinica, 2010, 30(11): 3191

    [3] Wang Luyang, Da Feipeng. Three-Dimensional Shape Measurement Technique Based on Complementary Color-Encoded Fringe Projection[J]. Acta Optica Sinica, 2011, 31(6): 612004

    [4] An Dong, Gai Shaoyan, Da Feipeng. A New Model of Three-Dimensional Shape Measurement System Based on Fringe Projection[J]. Acta Optica Sinica, 2014, 34(5): 512004

    [5] Zhang Chao, Duan Fajie, Xing Minghao, Hu Bo. Fiber-Optic Interferometer Projection of Real-Time Fourier Profilometry[J]. Acta Optica Sinica, 2011, 31(2): 207001

    [6] Zhangying Wang, Nan Gao, Zonghua Zhang. Three-Dimensional Shape Measurement Based on Parallel Four Color Channels Fringe Projection[J]. Acta Optica Sinica, 2018, 38(8): 0815022

    [7] Ma Suodong, Zhu Rihong, Li Jianxin, Gao Zhishan, Luo Hong′e, Wang Hailin, Shan Xiaoqin. A Multi-View Measurement System for Three-Dimensional Surface Distribution of Transient Moving Target[J]. Chinese Journal of Lasers, 2010, 37(12): 3091

    Tools

    Get Citation

    Copy Citation Text

    Wu Shuangqing, Zhang Yin, Zhang Sanyuan, Ye Xiuzi. Analysis of Three-Dimensional Measurement System and the Coordinates Calibration in Fourier Transform Profilometry[J]. Acta Optica Sinica, 2009, 29(10): 2780

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Nov. 11, 2008

    Accepted: --

    Published Online: Oct. 19, 2009

    The Author Email: Shuangqing Wu (wsqing1999@163.com)

    DOI:10.3788/aos20092910.2780

    Topics