Chinese Journal of Lasers, Volume. 32, Issue 2, 167(2005)

Experimental Research on Hard X-Ray Phase-Contrast Imaging

[in Chinese]1、*, [in Chinese]1, [in Chinese]1, [in Chinese]1, [in Chinese]1, [in Chinese]2, [in Chinese]2, and [in Chinese]2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(7)

    [1] [1] C. David, B. Nohammer, H. H. Solak et al.. Differential X-ray phase contrast imaging using a shearing interferometer [J]. Appl. Phys. Lett., 2002, 81(17): 3287~3289

    [2] [2] U. Bonse, M. Hart. An X-ray interferometer (Si) (E/T)[J]. Appl. Phys. Lett., 1965, 6(8):155~156

    [3] [3] V. N. Ingal, E. A. Beliaevskaya. X-ray plane-wave topography observation of the phase contrast from a non-crystalline object [J]. J. Phys. D: Appl. Phys., 1995, 28(11):2314~2317

    [4] [4] T. J. Davis, T. E. Gureyer, D. Gao et al.. X-ray image contrast from a simple phase object [J]. Phys. Rew. Lett., 1995, 74(16):3173~3176

    [5] [5] G. Schmahl, D. Rudolph, P. Guttmann et al.. Phase contrast studies of biological specimens with the x-ray microscope at BESSY(invited) [J]. Rev. Sci. Instrum., 1995, 66(2):1282~1286

    [6] [6] S. W. Wilkins, T. E. Gureyev, D. Gao et al.. Phase-contrast imaging using polychromatic hard X-rays [J]. Nature, 1996, 384(6607):335~338

    [8] [8] A. Pogany, D. Gao, S. W. Wilkins. Contrast and resolution in imaging with a microfocus x-ray source [J]. Rev. Sci. Instrum., 1997, 68(7):2774~2782

    CLP Journals

    [1] Hu Yanan, Wu Shengchuan, Zhang Siqi, Jiao Huisheng, Fu Yanan. Three-Dimensional X-Ray Micro-Tomography Based Microstructure and Mechanical Performance of Hybrid Laser Welded AA7020[J]. Chinese Journal of Lasers, 2016, 43(1): 103007

    [2] Xue Yanling, Xiao Tiqiao, Du Guohao, Liu Lixiang, Hu Wen, Xu Hongjie. Microscopic Identification of Panax Quinquefolium and Panax Ginseng by X-Ray Phase Contrast Imaging[J]. Acta Optica Sinica, 2008, 28(9): 1828

    [3] Duan Hao, Wu Shengchuan, Xu Zhongwei, Zhang Zhiliang, Kan Qianhua, Kang Guozheng, Fu Yanan. Damage Mechanism of Hybrid Welded 7020 Aluminium Alloy Based on Three-Dimensional X-Ray Micro-Tomography and GTN Model[J]. Chinese Journal of Lasers, 2016, 43(10): 1002005

    [4] Yang Min, Liu Jinghua, Li Baolei, Wu Wenjin, Wang Gang. Measurement Method of X-ray Focus Projection Coordinates of Three-Dimensional Micro-Computerized Tomography Scanning System[J]. Acta Optica Sinica, 2009, 29(5): 1275

    [5] Li Baolei, Yang Min, Fu Jian, Li Junjiang. Two Ring Artifact Correction Methods for Computed Tomagraphy[J]. Acta Optica Sinica, 2009, 29(7): 1849

    [6] Zhang Guoqiang, Zhou Hu, He You, Liu Huiqiang, Wang Yudan, Xue Yanling, Xie Honglan, Xiao Tiqiao. Ring Artifacts Correction of Computerized Tomography Image Based on Polar-Coordinate Transform[J]. Acta Optica Sinica, 2012, 32(5): 534001

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Experimental Research on Hard X-Ray Phase-Contrast Imaging[J]. Chinese Journal of Lasers, 2005, 32(2): 167

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 17, 2003

    Accepted: --

    Published Online: Jun. 1, 2006

    The Author Email: (gaohy@mail.shcnc.ac.cn)

    DOI:

    Topics