Chinese Optics Letters, Volume. 15, Issue 4, 040201(2017)

Recent improvements on the pulsed optically pumped rubidium clock at SIOM

Gongxun Dong1,2, Jianliao Deng1、*, Jinda Lin1、**, Song Zhang1, Haixiao Lin1,2, and Yuzhu Wang1
Author Affiliations
  • 1Key Laboratory of Quantum Optics, and Center for Cold Atom Physics, Shanghai Institute of Optics and Fine Mechanics (SIOM), Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(4)
    (a) Schematic setup of the POP clock with dispersive detection. PD, photodetector. (b) Timing sequence for the POP clock. Top red, optical pulses for state preparation and detection; middle blue, two microwave pulses for Ramsey interrogation; bottom yellow, trigger pulse for signal acquisition. These pulses correspond to the switches in different colors in (a). (c) Detailed energy level structure of Rb87 involved in the POP clock. The π transition between |52S1/2,F=1,mF=0〉 and |52S1/2,F=2,mF=0〉 is chosen as the clock transition with a frequency of about 6.8346 GHz.
    (a) Schematic of the new physics package. The cell filled with Rb87 and buffer gases has a size of ϕ20×20 mm fixed in a TE011 microwave cavity resonant at 6.8 GHz. The size of the physics package is about ϕ130×170 mm with a volume of about 2.2 L. (b) Microwave–light double resonance signal. The three peaks correspond to the π transitions (ΔmF=0) between hyperfine levels of Rb87. (c) Ramsey oscillating signal. We fixed the microwave frequency on the clock transition frequency and measured the Ramsey signal by changing the microwave power. (d) Ramsey fringe measured with the new physics package. The fringe has a contrast of about 97%, an SNR of about 2400, and a line width of about 140 Hz.
    (a) Fractional frequency under different temperatures. Black square, experimental data; red curve, fit line. (b) Temperature stability in terms of the Allan deviation and the Hadamard deviation under different average times.
    Frequency stability of the POP clock compared with the H maser. A drift of about −4.5×10−13/day is removed from the data. A clock frequency stability of 3.53×10−13 at 1 s is obtained, and the medium-term fractional frequency stability of 4.91×10−15 is achieved at an averaging time of τ=2000 s.
    Tools

    Get Citation

    Copy Citation Text

    Gongxun Dong, Jianliao Deng, Jinda Lin, Song Zhang, Haixiao Lin, Yuzhu Wang, "Recent improvements on the pulsed optically pumped rubidium clock at SIOM," Chin. Opt. Lett. 15, 040201 (2017)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atomic and Molecular Physics

    Received: Nov. 22, 2016

    Accepted: Jan. 6, 2017

    Published Online: Jul. 25, 2018

    The Author Email: Jianliao Deng (jldeng@siom.ac.cn), Jinda Lin (jinda@siom.ac.cn)

    DOI:10.3788/COL201715.040201

    Topics