Acta Optica Sinica, Volume. 43, Issue 12, 1201003(2023)

Fold-Path Atmospheric Coherence Length Measurement by Laser-Active Illumination Imaging

Junxin Zhang1,2,3, Haiping Mei1,3、*, Yichong Ren1,3, and Ruizhong Rao1,3
Author Affiliations
  • 1Key Laboratory of Atmospheric Optics, Chinese Academy of Sciences, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, Anhui, China
  • 2Science Island Branch of Graduate School, University of Science and Technology of China, Hefei 230026, Anhui, China
  • 3Advanced Laser Technology Laboratory of Anhui Province, Hefei 230037, Anhui, China
  • show less
    Figures & Tables(8)
    Schematic of the r0 measurement comparison experiment
    Schematic of the active illumination laser beam imaging experiment
    r0 measurement results of fold-path DIMM and traditional DIMM on October 27, 2021
    Ratio of fold-path DIMM and traditional DIMM measurement results on October 27, 2021
    Comparison of Cn2 inversion by centroid drift and DIMM under the circumstances of unfocused beam. (a) Distribution of measurement results; (b) correlation analysis between two measurements
    Comparison of Cn2 inversion by centroid drift and DIMM under the circumstances of focused beam. (a) Distribution of measurement results; (b) correlation analysis between two measurements
    • Table 1. Parameters of fold-path DIMM experiment

      View table

      Table 1. Parameters of fold-path DIMM experiment

      InstrumentParameter
      DIMM

      Focal length:2.845 m

      Subaperture diameter:0.12 m

      Subaperture separation:0.24 m

      Pixel size:4.54 µm

      Digit:14 bit

      Exposure time:200 µs

      Meade

      Model:ACF14F8

      Aperture:355 mm

      Focal length:2.845 m

      Allied Vison GT 1920 CCD

      Exposure range:10 µs-26.8 s

      Pixel size:4.54 µm

      Sample frequency up to 40.7 frame/s

      Resolution:1936 pixel×1456 pixel

    • Table 2. Parameters of the active illumination laser beam imaging experiment

      View table

      Table 2. Parameters of the active illumination laser beam imaging experiment

      InstrumentParameter
      DIMM

      Focal length:3.55 m

      Subaperture diameter:0.12 m

      Subaperture separation:0.24 m

      Pixel size:3.75 µm

      Digit:14 bit

      Exposure time:200 µs

      BOSMA

      Model:MK24020

      Aperture:200 mm

      Focal length:1200 mm

      ASI 290MM CCD

      Exposure range:32 µs-2000 s

      Pixel size:2.9 µm

      Sample frequency:330 Hz/560 Hz

      Resolution:1936 pixel×1096 pixel

    Tools

    Get Citation

    Copy Citation Text

    Junxin Zhang, Haiping Mei, Yichong Ren, Ruizhong Rao. Fold-Path Atmospheric Coherence Length Measurement by Laser-Active Illumination Imaging[J]. Acta Optica Sinica, 2023, 43(12): 1201003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Oct. 20, 2022

    Accepted: Nov. 30, 2022

    Published Online: Jun. 20, 2023

    The Author Email: Mei Haiping (hpmei@aiofm.ac.cn)

    DOI:10.3788/AOS221854

    Topics