Chinese Journal of Lasers, Volume. 48, Issue 24, 2406001(2021)

Surface Structure State Perception System Based on FBG Array

Lixin Yin1,2, Zhichao Liu1,2、*, and Chunhui Liu1,2
Author Affiliations
  • 1College of Optoelectronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • 2Key Laboratory of Optoelectronic Measurement and Control and Optical Information Transmission Technology of Ministry of Education, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • show less
    Figures & Tables(12)
    Schematic diagram of micro-element segment before and after deformation
    Schematic diagram of coordinate conversion
    Surface strain distributions of structure to be tested. (a) Load is 40 N; (b) load is 100 N
    Schematic diagram of overall system structure
    Physical distribution diagram of experimental device
    Schematic diagrams of fiber wavelength offsets at different pressure points. (a) Pressure point is at s1; (b) pressure point is at s2; (c) pressure point is at s3; (d) pressure point is at s4; (e) pressure point is at s5; (f) pressure point is at s6; (g) pressure point is at s7; (h) pressure point is at s8; (i) pressure point is at s9
    Comparison and analysis diagram of actually measured strain values and simulated values
    Three-dimensional surface reconstruction by MATLAB
    Three-dimensional surface map after Qualify point cloud processing
    • Table 1. Error analysis table when pressure point is at s2

      View table

      Table 1. Error analysis table when pressure point is at s2

      FBG numberDeformation value /mmAbsolute errorΔ /mmRelative errorσ /%
      ANSYSFBGHandyscan
      10.2150.2310.2210.0104.32
      20.2390.2520.2440.0083.17
      30.3510.4030.3770.0266.45
      40.3270.3120.3010.0113.52
      50.1340.1490.1420.0074.70
      60.1380.1510.1410.0106.62
    • Table 2. Error analysis table when pressure point is at s9

      View table

      Table 2. Error analysis table when pressure point is at s9

      FBG numberDeformation value /mmAbsolute errorΔ /mmRelative errorσ /%
      ANSYSFBGHandyscan
      10.2140.2210.2230.0020.90
      20.2290.2330.2460.0135.58
      30.1130.1230.1150.0086.50
      40.1020.1120.1050.0076.25
      50.3350.3420.3310.0113.22
      60.3290.3350.3270.0082.39
    • Table 3. Error analysis table when pressure point is at s7

      View table

      Table 3. Error analysis table when pressure point is at s7

      FBG numberDeformation value /mmAbsolute errorΔ /mmRelative errorσ /%
      ANSYSFBGHandyscan
      10.1230.1410.1360.0053.54
      20.1320.1350.1260.0096.67
      30.2520.2570.2460.0114.28
      40.2470.2520.2680.0166.35
      50.3120.3240.3370.0134.01
      60.3310.3490.3380.0113.15
    Tools

    Get Citation

    Copy Citation Text

    Lixin Yin, Zhichao Liu, Chunhui Liu. Surface Structure State Perception System Based on FBG Array[J]. Chinese Journal of Lasers, 2021, 48(24): 2406001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: fiber optics and optical communications

    Received: Mar. 22, 2021

    Accepted: May. 17, 2021

    Published Online: Nov. 22, 2021

    The Author Email: Liu Zhichao (lzc@cust.edu.cn)

    DOI:10.3788/CJL202148.2406001

    Topics