Acta Optica Sinica, Volume. 38, Issue 4, 0401002(2018)

Equivalent Emissivity Inversion Method for Infrared Filters in Cutoff Band

Junchi Liu*, Hongwen Li*, Limei Yin, and Hongzhuang Li
Author Affiliations
  • Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130039, China
  • show less
    References(19)

    [1] Li Y, Liu J F. Research on integrative suppression of internal and external stray light in infrared optical remote sensor[J]. Acta Optica Sinica, 33, 0928002(2013).

    [5] Fest E[M]. Stray light analysis and control, 41-59(2013).

    [6] Chang S T, Sun Z Y, Zhang Y Y et al. Internal stray radiation measurement for cooled infrared imaging systems[J]. Acta Physica Sinica, 64, 050702(2015).

    [7] Tian Q J, Chang S T, He F Y et al. Internal stray radiation measurement for cooled infrared imaging systems using ambient temperature[J]. Acta Optica Sinica, 37, 0712002(2017).

    [12] Liu J C, Li H W, Wang J L et al. Fast radiance calibration for ground-based large-aperture infrared opto-electric equipment[J]. Acta Optica Sinica, 35, 0301003(2015).

    [13] Liu J C, Li H W, Wang J L et al. Measurement of mid-infrared total atmospheric transmittance and its error analysis[J]. Optics and Precision Engineering, 23, 1547-1557(2015).

    [14] Yu Y, Chang S T, Wang M et al. Fast non-uniformity correction for high dynamic infrared radiometric system[J]. Optics and Precision Engineering, 23, 1932-1938(2015).

    [15] Guo L H, Guo H Z, Yang C Y et al. Improvement of radiation measurement precision for target by using atmosphere-corrected coefficients[J]. Optics and Precision Engineering, 24, 1871-1877(2016).

    [16] Zhang J M, Feng G B, Yang P L et al. Thermal issues of photoconductive HgCdTe detector in mid-infrared laser parameter measurement[J]. Optics and Precision Engineering, 23, 22-30(2015).

    [17] Siegel R, Howell J R[M]. Thermal radiation heat transfer, 65-71(1992).

    [18] Peng Z Y, Wang X J, Lu J. Method of imaging performance deterioration analysis and its experiment simulated high heating sapphire MW infrared window during near-hypersonic flight[J]. Acta Physica Sinica, 62, 230702(2013).

    [19] Jin N, Yang K Y, Cao L et al. Optimization design for the shapes of cold shield in infrared systems[J]. Acta Optica Sinica, 36, 0111005(2016).

    Tools

    Get Citation

    Copy Citation Text

    Junchi Liu, Hongwen Li, Limei Yin, Hongzhuang Li. Equivalent Emissivity Inversion Method for Infrared Filters in Cutoff Band[J]. Acta Optica Sinica, 2018, 38(4): 0401002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Sep. 28, 2017

    Accepted: --

    Published Online: Jul. 10, 2018

    The Author Email: Liu Junchi (lihongwen@ciomp.ac.cn), Li Hongwen (lihongwen@ciomp.ac.cn)

    DOI:10.3788/AOS201838.0401002

    Topics