Laser & Optoelectronics Progress, Volume. 54, Issue 12, 122501(2017)

Fast Radiometric Calibration Method for Long Wave Infrared Detectors

Nan Tongling1,2, Shen Honghai1、*, Yang Mingyu1, Chen Cheng1, and Zhu Dantong1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(16)

    [1] [1] Griggs M, Myers W A, Baker H V. Multispectral sensing of natural resources with the MSTI-3 satellite[C]. Multispectral and Microwave Sensing of Forestry, Hydrology, and Natural Resources, 1995, 2314: 192-200.

    [3] [3] Li Xiansheng, Ren Jianwei, Zhang Liguo, et al. Research on a radiometric calibration device for a large aperture infrared optoelectric system on spot[J]. Journal of Optoelectronics·Laser, 2006, 17(2): 175-178.

    [4] [4] Liang Chao, Ma Tianxiang. Design of infrared imaging nonuniformity correction system based on black body calibration[J]. Chinese Optics, 2016, 9(3): 385-393.

    [5] [5] Yang Ciyin, Cao Lihua. Radiation calibration and error analysis for a large-aperture infrared opto-electric system[J]. Infrared and Laser Engineering, 2011, 40(9): 1624-1628.

    [6] [6] Cao Lihua, Li Ning, Yang Ciyin, et al. Radiance calibration for 3~5 μm infrared detector[J]. Infrared and Laser Engineering, 2012, 41(4): 858-864.

    [8] [8] Sun Zhiyuan, Chang Songtao, Zhu Wei. Radiation calibration method for infrared system with large aperture and broad dynamic range[J]. Acta Optica Sinica, 2014, 34(7): 0712006.

    [9] [9] Wang Jianjun, Huang Chen, Gao Xin, et al. Inner and outer calibration technology of infrared radiation measurement[J]. Infrared and Laser Engineering, 2014, 43(6): 1767-1771.

    [10] [10] Wang Jianjun, Huang Chen, Li Jianting, et al. Calibration technology of infrared radiation measurement for space object[J]. Infrared and Laser Engineering, 2016, 45(4): 98-102.

    [11] [11] Liu Yingqi, Liu Xiangyi. Research on technology of ground-based infrared radiation feature measurement for space target[J]. Acta Optica Sinica, 2014, 34(5): 0512003.

    [12] [12] Luo Maojie, Zhou Jinmei, Fu Jingneng, et al. Integration time as variable for radiometric calibration of infrared system[J]. Infrared and Laser Engineering, 2013, 42(1): 36-40.

    [13] [13] Lü You. Research on technology of middle-infrared-based dual-band target′s radiation characteristics measurement[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2016.

    [14] [14] Sun Zhiyuan, Chang Songtao, Zhu Wei. Simplifying method of radiance calibration for MWIR detector[J]. Infrared and Laser Engineering, 2014, 43(7): 2132-2137.

    [15] [15] Ma Hong, Wang Jinbo. Theory of error and precision of instrument[M]. Beijing: Weapon Industry Press, 2007.

    Tools

    Get Citation

    Copy Citation Text

    Nan Tongling, Shen Honghai, Yang Mingyu, Chen Cheng, Zhu Dantong. Fast Radiometric Calibration Method for Long Wave Infrared Detectors[J]. Laser & Optoelectronics Progress, 2017, 54(12): 122501

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: OPTOELECTRONICS

    Received: Jul. 10, 2017

    Accepted: --

    Published Online: Dec. 11, 2017

    The Author Email: Shen Honghai (shenhh@ciomp.ac.cn)

    DOI:10.3788/lop54.122501

    Topics