Acta Optica Sinica, Volume. 41, Issue 21, 2122001(2021)

Stability of Air Floating Optical Platform Based on Optimal Tuned Liquid Column Damper

Wenhui Cui1,2、*, Jianqiang Zhu1、**, Yuanqi He1,2, Zhigang Liu1, Quantang Fan1, Weiheng Lin1,2, and Ziming Dong1
Author Affiliations
  • 1Joint Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    References(13)

    [1] Zhu J Q, Zeng T Y, Pang X Y et al. Primary discussion on engineering stability[J]. Laser & Optoelectronics Progress, 45, 16-23(2008).

    [2] Zhang W, Cui D, Cui Y J et al. Modal testing and analysis of optical platform[J]. High Power Laser and Particle Beams, 25, 71-76(2013).

    [3] Zhou Y, Li C W, Xu X B et al. Parameter optimization design of air-floating platform system for optical testing instrument of liquid crystal glass panel[J]. Acta Metrologica Sinica, 40, 994-999(2019).

    [4] Feng S Y, Liu C S, Gu J J et al. Evaluation of stability of holographic platform by digital phase-shifting interferometer[J]. Physics Experimentation, 33, 23-26(2013).

    [6] Reiterer M, Hochrainer M. Damping of pedestrian-induced bridge vibrations by tuned liquid column dampers[J]. Pamm, 4, 109-110(2004).

    [7] Ruiz R O, Lopez-Garcia D, Taflanidis A A. Modeling and experimental validation of a new type of tuned liquid damper[J]. Acta Mechanica, 227, 3275-3294(2016).

    [8] Gao H. Kwok K S C, Samali B. Characteristics of multiple tuned liquid column dampers in suppressing structural vibration[J]. Engineering Structures, 21, 316-331(1999).

    [9] Balendra T, Wang C M, Rakesh G. Effectiveness of TLCD on various structural systems[J]. Engineering Structures, 21, 291-305(1999).

    [10] Lan W W. Study on the effectiveness of MTLDs in suppressing the earthquakes-induced motions in highrise building[J]. World Information on Earthquake Engineering, 17, 59-64(2001).

    [11] Chen B, Zhang Z L, Hua X G. Closed-form optimal calibration of a tuned liquid column damper (TLCD) for flexible structures[J]. International Journal of Mechanical Sciences, 198, 106364(2021).

    [12] Wang Z, Cao L, Ubertini F et al. Numerical investigation and design of reinforced concrete shear wall equipped with tuned liquid multiple columns dampers[J]. Shock and Vibration, 2021, 6610811(2021).

    [13] Wang Q H, Tiwari N D, Qiao H S et al. Inerter-based tuned liquid column damper for seismic vibration control of a single-degree-of-freedom structure[J]. International Journal of Mechanical Sciences, 184, 105840(2020).

    [14] Yalla S K, Kareem A. Optimum absorber parameters for tuned liquid column dampers[J]. Journal of Structural Engineering, 126, 906-915(2000).

    Tools

    Get Citation

    Copy Citation Text

    Wenhui Cui, Jianqiang Zhu, Yuanqi He, Zhigang Liu, Quantang Fan, Weiheng Lin, Ziming Dong. Stability of Air Floating Optical Platform Based on Optimal Tuned Liquid Column Damper[J]. Acta Optica Sinica, 2021, 41(21): 2122001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: May. 17, 2021

    Accepted: May. 29, 2021

    Published Online: Nov. 17, 2021

    The Author Email: Wenhui Cui (whcui@siom.ac.cn), Jianqiang Zhu (jqzhu@siom.ac.cn)

    DOI:10.3788/AOS202141.2122001

    Topics