Chinese Journal of Lasers, Volume. 50, Issue 9, 0907204(2023)

Precision Cornea Alignment Method Based on Two‐Light‐Spot Vision Marker

Mengyuan Zhao1,2, Haomin Yang2, Dewen Xu4, Lin Ji1,2, Yulong Liu3, and Yunhai Zhang1,2、*
Author Affiliations
  • 1Division of Life Sciences and Medicine, School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, Anhui, China
  • 2Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, Jiangsu, China
  • 3The second affiliated hospital of Soochow University, Suzhou 215004, Jiangsu, China
  • 4College of Science, Hohai University, Changzhou 213022, Jiangsu, China
  • show less
    Figures & Tables(9)
    Schematic of cornea alignment optical path
    Schematics of cornea alignment method based on two-light-spot vision marker. (a) d=D0; (b) d>D0; (c) d0
    Cornea alignment optical path. (a) Path for light incident on cornea surface through two-aperture diaphragm; (b) path for two light beams reflected from cornea convergent through objective lens ( solid line indicates that cornea is at correct working position, and dashed line indicates that cornea is away from correct working position)
    Alignment range and precision of two-light-spot vision marker. (a) Schematic diagram of out-of-alignment-range; (b) ZEMAX simulation of out-of-alignment-range; (c) ZEMAX simulation of alignment precision
    Relationships of aperture distance in two-aperture diaphragm with alignment range and precision. (a) Aperture distance and alignment range; (b) aperture distance and alignment precision
    Alignment optical path with two-light-spot vision marker
    Images of two spots on CMOS under different Δ. (a) Δ=4.6 mm; (b) Δ=-3.6 mm; (c) Δ=0.25 mm; (d) Δ=-0.25 mm;
    Effect of d on positions of two light spots. (a) Relationship between distance of two separated light spots and d; (b) distance from light spot to focus point versus d
    Fundus images for two light spots with different states. (a)-(e) Fundus color photos; (f)-(j) near infrared images of fundus; (k)-(o) locally enlarged image
    Tools

    Get Citation

    Copy Citation Text

    Mengyuan Zhao, Haomin Yang, Dewen Xu, Lin Ji, Yulong Liu, Yunhai Zhang. Precision Cornea Alignment Method Based on Two‐Light‐Spot Vision Marker[J]. Chinese Journal of Lasers, 2023, 50(9): 0907204

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Diagnostics and Therapy

    Received: Oct. 21, 2022

    Accepted: Dec. 6, 2022

    Published Online: Apr. 24, 2023

    The Author Email: Zhang Yunhai (zhangyh@sibet.ac.cn)

    DOI:10.3788/CJL221349

    Topics