Acta Optica Sinica, Volume. 31, Issue 11, 1112001(2011)
Error Analysis and Correction during Measurement of Tube-Shaped Super-Smooth Mirrors Using Long Trace Profiler
[1] [1] James R. Lemen, Dexter Duncan, Christopher Edwards et al.. The solar X-ray imager for GOES[C]. SPIE, 2004, 5171: 65~76
[2] [2] Li Baoquan, Zhu Guangwu, Wang Shijin et al.. The solar X-EUV imaging telescope[J]. Chinese J. Geophysics, 2005, 48(2): 235~242
[4] [4] James E. Harvey, Andrey Krywonos, Patrick L. Thompson et al.. Grazing-incidence hyperboloid-hyperboloid designs for wide-field X-ray imaging applications[J]. Appl. Opt., 2001, 40(1): 136~144
[5] [5] Timo T. Saha, William Zhang. Equal-curvature grazing-incidence X-ray telescopes[J]. Appl. Opt., 2003, 42(22): 4599~4605
[7] [7] Patrick L. Thompson, James E. Harvey. Systems engineering analysis of aplanatic Wolter type I X-ray telescopes[J]. Opt. Engng., 2000, 39(6): 1677~1691
[8] [8] Shinan Qian, Haizhang Li, Peter Z. Takacs. Penta-prism long trace profiler (PPLTP) for measurement of grazing incidence space optics[C]. SPIE, 1996, 2805: 108~114
[9] [9] Haizhang Li, Xiaodan Li, Manfred W. Grindel et al.. Measurement of X-ray telescope mirrors using a vertical scanning long trace profiler[J]. Opt. Engng., 1996, 35(2): 330~338
[10] [10] Peter Z. Takacs, Shinan. Qian, J. Colbert. Design of a long-trace surface profiler[C]. SPIE, 1987, 749: 59~64
[11] [11] Yang Zhao, Zhi Li, Dacheng Li et al.. Principle of π-phase plate long trace profiler for synchrotron radiation optics[J]. Opt. Commun., 2001, 200(1-6): 23~26
[13] [13] Shinan Qian, Peter Z. Takacs. Equal optical path beamspliter for a pencil beam interferometer and shearing interferometer[J]. Opt. Engng., 2003, 42(4): 929~934
[14] [14] Shinan Qian, Peter Z. Takacs. Design of multiple-function long trace profiler[J]. Opt. Engng., 2007, 46(4): 043602
[15] [15] Haizhang Li, Peter Z. Takacs, Tom Oversluizen. Vertical scanning long trace profiler: a tool for metrology of X-ray mirrors[C]. SPIE, 1997, 3152: 180~187
[16] [16] Li Shun, Gong Yan, Zhang Wei et al.. Design of co-path scanning long trace profiler for measurement of X-ray space optical elements[C]. SPIE, 2010, 7544: 754421
[18] [18] Cui Tiangang, Zhang Hongji, Ma Dongmei et al.. Improvements of surface profile measuring device for Wolter type-I mirror [J]. Acta Optica Sinica, 2011, 31(4): 0412007
[19] [19] Shinan Qian, Giovanni Sostero, Peter Z. Takacs. Precision calibration and systematic error reduction in the long trace profiler [J]. Opt. Engng., 2000, 39(1): 304~310
[20] [20] Peter Z. Takacs, Eugene L. Church, Cynthia J. Bresloff et al.. Improvements in the accuracy and the repeatability of long trace profiler measurements[J]. Appl. Opt., 1999, 38(25): 5468~5479
[21] [21] Peter Z. Takacs. Cylinder lens alignment in the LTP[C]. SPIE, 2005, 5921: 592105
[22] [22] Valeriy V. Yashchuk, Steve C. Irick, Alastair A. MacDowell et al.. Air convection noise of pencil-beam interferometer for long trace profiler[C]. SPIE, 2006, 6317: 63170D
[23] [23] Eric Marsh, Jeremiah Couey, Ryan Vallance. Nanometer-level comparison of three spindle error motion separation techniques[J]. ASME J. Manuf. Sci. Engng., 2006, 128(1): 180~187
Get Citation
Copy Citation Text
Li Shun, Gong Yan. Error Analysis and Correction during Measurement of Tube-Shaped Super-Smooth Mirrors Using Long Trace Profiler[J]. Acta Optica Sinica, 2011, 31(11): 1112001
Category: Instrumentation, Measurement and Metrology
Received: May. 4, 2011
Accepted: --
Published Online: Oct. 12, 2011
The Author Email: Shun Li (lishun156@163.com)