Chinese Journal of Lasers, Volume. 40, Issue 1, 115003(2013)
A High Sensitive Spectral Detection System of Gaseous Measurement Based on LabVIEW
[1] [1] R. Engeln, G. Berden, R. Peeter et al.. Cavity enhanced absorption and enhanced absorption magnetic rotation spectroscopy[J]. Rev. Sci. Instrum., 1998, 69(11): 3763~3769
[2] [2] A. O′Keefe. Integrated cavity output analysis of ultra-weak absorption[J]. Chem. Phys. Lett., 1998, 293(5-6): 331~336
[3] [3] A. O′Keefe, J. J. Scherer, J. B. Pual. CW integrated cavity output spectroscopy[J]. Chem. Phys. Lett., 1999, 307(5-6): 343~349
[4] [4] R. Peeters, G. Berden, A. Apituley et al.. Open-path gas detection of ammonia based on cavity-enhanced absorption spectroscopy[J]. Appl. Phys. B, 2000, 71(2): 231~236
[5] [5] V. L. Kasyutich, C. S. E. Bale, C. E. Canosa-Mas et al.. Cavity-enhanced absorption: detection of nitrogen dioxide and iodine monoxide using a violet laser[J]. Appl. Phys. B, 2003, 76(6): 691~697
[6] [6] P. S. Johnston, K. K. lehmann. Cavity enhanced absorption spectroscopy using a broadband prism cavity and a supercontinuum source[J]. Opt. Express, 2008, 16(19): 15013~15023
[7] [7] Fan Fengying, Song Zengyun. Measurement of CO2 concentration with tunable diode laser absorption spectroscopy near 2 μm[J]. Chinese J. Lasers, 2012, 39(2): 0215002
[8] [8] Rubin Qi, Zhenhui Du, Dongyu Gao et al.. Wavelength modulation spectroscopy based on quasi-continuous-wave diode lasers[J]. Chin. Opt. Lett., 2012, 10(3): 033001
[9] [9] A. O′Keefe, D. A. G. Deaon. Cavity ring-down optical spectrometer for absorption-measurements using pulsed laser sources[J]. Rev. Sci. Instrum., 1988, 59(12): 2544~2551
[10] [10] D. Romanini, A. A. Kachanov, N. Sadeghi et al.. CW cavity ringdown absorption spectroscopy[J]. Chem. Phys. Lett., 1997, 264(3-4): 316~322
[11] [11] J. B. Paul, L. Lapson, J. G. Anderson. Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment[J]. Appl. Opt., 2001, 40(27): 4904~4910
[12] [12] D. S. Baer, J. B. Paul, M. Gupta et al.. Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy[J]. Appl. Phys. B, 2002, 75(2-3): 261~265
[14] [14] V. L. Kasyutich, P. A. Martin, R. J. Holdsworth et al.. An off-axis cavity-enhanced absorption spectrometer at 1605 nm for the 12CO2/13CO2 measurement[J]. Appl. Phys. B, 2006, 85(2-3): 413~420
[15] [15] D. R. Herriott, H. Kogelnik, R. Kompfner. Off-axis paths in spherical mirror interferometers[J]. Appl. Opt., 1964, 3(4): 523~526
[16] [16] D. R. Herriott, H. J. Shulte. Folded optical delay lines[J]. Appl. Opt., 1965, 4(8): 883~889
Get Citation
Copy Citation Text
Long Jingming, Zhou Weidong, Wu Zhiwei. A High Sensitive Spectral Detection System of Gaseous Measurement Based on LabVIEW[J]. Chinese Journal of Lasers, 2013, 40(1): 115003
Category: Spectroscopy
Received: Aug. 2, 2012
Accepted: --
Published Online: Dec. 21, 2012
The Author Email: Jingming Long (jmlong@yahoo.cn)