Spectroscopy and Spectral Analysis, Volume. 40, Issue 12, 3665(2020)

Based on TDLAS Technology Gas Concentration Calibration Algorithm for a Large Range

Yu JU1,1, Hao CHEN1,1, Li HAN1,1, Yang CHANG1,1, and Xue-jian ZHANG1,1
Author Affiliations
  • 1[in Chinese]
  • 11. Beijing Aerospace Yilian Science and Technology Development Company, Beijing 100176, China
  • show less
    Figures & Tables(9)
    The simulation curve of gas concentration vs Ratio
    Spectra of water vapor absorption peaks in the range of 1 365 to 1 370 nm
    Schematic diagram of the experimental device
    Gas concentration and transmittance logarithm curve, fitting curve and relative error curve
    The fitting curve of 1/c vs 1/Ratio. The fitting curve using 1/c method and relative error
    Relative errors of polynomial fitting and 1/c method
    • Table 1. Results of water vapor absorption spectrum intensity ratio at different concentrations

      View table
      View in Article

      Table 1. Results of water vapor absorption spectrum intensity ratio at different concentrations

      Test PointRatio(TDLAS)Vaisala
      10.0550.007 769
      20.090.012 472
      30.1190.016 488
      40.1510.021 447
      50.210.029 245
      60.2830.041 825
      70.3660.056 189
      80.4670.075 468
      90.6050.103 657
      100.7160.133 202
      110.860.180 476
      120.9720.224 848
      131.080.276 66
      141.1640.323 603
      151.2080.359 264
      161.2670.400 745
      171.2980.439 54
      181.3340.498 216
    • Table 2. Correlation coefficient and root mean square error of three fitting curves

      View table
      View in Article

      Table 2. Correlation coefficient and root mean square error of three fitting curves

      Primary
      polynomial
      Quadratic
      polynomial
      Quintic
      polynomial
      R20.946 80.996 70.999 9
      RMSE0.031 20.007 80.001 6
    • Table 3. Results of polynomial fitting and 1/c method

      View table
      View in Article

      Table 3. Results of polynomial fitting and 1/c method

      Standard
      Concentration
      Quadratic
      Polynomial
      Quintic
      Polynomial
      1/c
      method
      10%0.098 20.102 60.102 8
      20%0.210 70.201 60.201 9
      30%0.308 30.301 70.301 4
      40%0.386 70.399 70.399 7
      50%0.451 80.496 60.500 5
      60%0.507 80.593 50.607 4
      70%0.544 40.664 40.691 1
    Tools

    Get Citation

    Copy Citation Text

    Yu JU, Hao CHEN, Li HAN, Yang CHANG, Xue-jian ZHANG. Based on TDLAS Technology Gas Concentration Calibration Algorithm for a Large Range[J]. Spectroscopy and Spectral Analysis, 2020, 40(12): 3665

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Oct. 28, 2019

    Accepted: --

    Published Online: Jun. 18, 2021

    The Author Email:

    DOI:10.3964/j.issn.1000-0593(2020)12-3665-05

    Topics