High Power Laser and Particle Beams, Volume. 35, Issue 9, 094002(2023)

Energy adjustment and application of the HLS-II linac

Wangbiao Ni, Yongbo Yu, Ke Xuan*, Wei Xu, Chuan Li, and Gongfa Liu
Author Affiliations
  • National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026, China
  • show less
    Figures & Tables(9)
    Layout of the HLS-II linac and some components behind the switch magnet
    Flowchart of the automatic phase scanning program
    Automatic phase scanning interface
    Relationship between high voltage and peak acceleration phase and relationship between high voltage and maximum energy gain for KLY7 and KLY8
    Schematic diagram of phase adjustment
    Comparison of energy spread before and after beam energy adjustment
    Comparison of beam energy and injection rate before and after opening energy adjustment during injection stage
    • Table 1. Automatic phase scanning results of KLY3~KLY8

      View table
      View in Article

      Table 1. Automatic phase scanning results of KLY3~KLY8

      klystronpeak output power/MWoperating high voltage/kVenergy gain formula
      KLY35044${E_3} = 97.78\cos ({\varphi _3} + 179.38^\circ )$
      KLY45044${E_4} = 93.64\cos ({\varphi _4} - 173.98^\circ )$
      KLY55044${E_5} = 90.66\cos ({\varphi _5} + 79.58^\circ )$
      KLY65044${E_6} = 95.16\cos ({\varphi _6} + 31.04^\circ )$
      KLY75044${E_7} = 96.16\cos ({\varphi _7} + 148.82^\circ )$
      KLY88044${E_8} = 124.01\cos ({\varphi _8} + 38.11^\circ )$
    • Table 2. Fitting results of the high voltage with peak acceleration phase and the high voltage with maximum energy gain for KLY7 and KLY8

      View table
      View in Article

      Table 2. Fitting results of the high voltage with peak acceleration phase and the high voltage with maximum energy gain for KLY7 and KLY8

      klystronfitting results of klystron high voltage and maximum energy gain fitting results of klystron high voltage and peak acceleration phase
      KLY7${A_7} = 2.93{U_7} - 33.06$${\varphi _{7\max}} = - 9.77{U_7} + 280.9$
      KLY8${A_8} = 4.95{U_8} - 96.35$${\varphi _{8\max}} = - 10.52{U_8} + 425.8$
    Tools

    Get Citation

    Copy Citation Text

    Wangbiao Ni, Yongbo Yu, Ke Xuan, Wei Xu, Chuan Li, Gongfa Liu. Energy adjustment and application of the HLS-II linac[J]. High Power Laser and Particle Beams, 2023, 35(9): 094002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Particle Beams and Accelerator Technology

    Received: May. 24, 2023

    Accepted: Jul. 19, 2023

    Published Online: Oct. 17, 2023

    The Author Email: Xuan Ke (xuanke@ustc.edu.cn)

    DOI:10.11884/HPLPB202335.230144

    Topics