Acta Optica Sinica, Volume. 43, Issue 11, 1114001(2023)

Angle-Resolved Stimulated Brillouin Backscattering Diagnosis System Based on Shenguang-Ⅱ Upgrade Facility

Chuang Zhao1, Peng Yuan1、*, Xinyan Li1, and Jian Zheng1,2
Author Affiliations
  • 1School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, Anhui , China
  • 2Collaborative Innovation Center of IFSA, Shanghai Jiao Tong University, Shanghai 200240, China
  • show less
    Figures & Tables(11)
    Diagnosis principles. (a) System design; (b) time evolution spectrum of third harmonic signals from servo mirror recorded by spectrometer-streak camera
    Signal collection module design. (a) Mechanical structure diagram of signal collection module; (b) signal collection effect of signal collection module; (c) on-site arrangement of signal collection module
    Energy fraction diagnostic module
    Characteristics of energy fraction diagnostics module: (a) Gating time characteristic of ICCD; (b) response ratio calibration result of two branches in energy fraction diagnostic module
    Experimental conditions for DCI 2021 winter experiment. (a) Waveform conditions; (b) golden cone and laser irradiation condition (laser focusing distance from crown of 100 μm)
    Original diagram of diagnostic results. (a) Intensity of laser signal; (b) intensity of SBS signal
    Distribution of SBS backscattering energy fraction in B area. (a) Spherical crown target (laser focal spot superimposed 100 μm below crown top); (b) spherical crown target (laser focal spot superimposed 125 μm below crown top); (c) spherical crown target (laser focal spot superimposed 150 μm below crown top); (d) planar target (upper surface of laser focal spot target)
    Errors caused by ICCD trigger jitter and gating characteristic. (a) Time relationship among ICCD gating time characteristic, reflected laser signal part from rear surface of frequency-triple-conversion crystal and stray signal generated by primary and secondary debris shields under experimental set delay; (b) effect of ICCD trigger jitter on signal acquisition
    • Table 1. Distribution of SBS backscattering energy fraction

      View table

      Table 1. Distribution of SBS backscattering energy fraction

      Shot No.A1A2A3B1B2B3C1C2C3
      1142.50%4.10%7.94%2.33%1.62%2.39%1.21%1.75%0.08%
    • Table 2. Response ratio calibration error of each channel

      View table

      Table 2. Response ratio calibration error of each channel

      ChannelA1A2A3B1B2B3C1C2C3
      Ratio calibration±6.56%±6.10%±5.21%±12.86%±9.58%±7.62%±5.83%±5.50%±7.58%
    • Table 3. Diagnostic uncertainty for each channel

      View table

      Table 3. Diagnostic uncertainty for each channel

      ChannelA1A2A3B1B2B3C1C2C3
      Uncertainty±9.65%±9.34%±8.79%±14.67%±11.91%±10.40%±9.17%±8.96%±10.37%
    Tools

    Get Citation

    Copy Citation Text

    Chuang Zhao, Peng Yuan, Xinyan Li, Jian Zheng. Angle-Resolved Stimulated Brillouin Backscattering Diagnosis System Based on Shenguang-Ⅱ Upgrade Facility[J]. Acta Optica Sinica, 2023, 43(11): 1114001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and Laser Optics

    Received: Nov. 15, 2022

    Accepted: Feb. 7, 2023

    Published Online: May. 9, 2023

    The Author Email: Peng Yuan (yuanpeng@ustc.edu.cn)

    DOI:10.3788/AOS221987

    Topics