Chinese Journal of Lasers, Volume. 38, Issue 4, 408002(2011)

Effect of Beat Frequency Linetype on Measurement of Laser Linewidth Using Two Independent Lasers

Peng Xuefeng1,2、*, Ma Xiurong1,2, Zhang Shuanggen1,2, Ren Guangjun1,2, and Liu Tao1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(11)

    [1] [1] P. Signoret, M. Myara, J. P. Tourrenc et al.. Bragg section effects on linewidth and lineshape in 1.55 μm DBR tunable laser diodes [J]. IEEE Photon. Technol. Lett., 2004, 16(6):1429~1431

    [5] [5] Lwatsukik, H. Okamura, I. M. Saruwatar. Wavelength tunable single frequency and single polarization Er-doped fiber ring laser width 1.4 kHz linewidth [J]. Electron. Lett., 1990, 26(24):2033~2034

    [6] [6] A. Debut, S. Randoux, I. J. Zermmour. Line-width narrowing in Brillouin lasers: Theoretical analysis [J]. Phys. Rev. A, 2000, 62(2):023803

    [7] [7] Jia Yudong, Ou Pan, Yang Yuanhong et al.. Short fiber delayed self-heterodyne interferometer for ultranarrow laser linewidth measurement [J]. Journal of Beijing University of Aeronautics and Astronautics, 2008, 34(5):568~571

    [8] [8] Namkyoo Park, W. Dawson Jay, J. Vahala Kerry. Linewidth and frequency jitter measurement of an erbium-doped fiber ring laser by using a loss-compensated delayed self-heterodyne interferometer [J]. IEEE Photon. Technol. Lett., 1992, 4(9):1063~1066

    [9] [9] Qu Ronghui, Cai Haiwen. Narrow linewidth lasers with high stability [J]. Infrared and Laser Engineering, 2009, 38(6):1033~1038

    [10] [10] L. E. Richter, H. I. Mandelberg, M. S. Kriger et al.. Linewidth determination form self-heterodyne measurements with subcoherence delay time [J]. Quantum Electron. Lett., 1986, 22(11):2070~2074

    [11] [11] Liu Xiaobo. Measurement System Design and Implementation of Narrow Linewidth of Semiconductor Laser [D]. Nanjing: Nanjing University of Science and Technology, 2009

    CLP Journals

    [1] Bai Jiandong, Wang Jieying, Wang Junmin. Rapid Measurement of Laser Linewidth Based on Fiber-Delayed AOM-Shifted Self-Heterodyne Scheme[J]. Laser & Optoelectronics Progress, 2016, 53(6): 61407

    Tools

    Get Citation

    Copy Citation Text

    Peng Xuefeng, Ma Xiurong, Zhang Shuanggen, Ren Guangjun, Liu Tao. Effect of Beat Frequency Linetype on Measurement of Laser Linewidth Using Two Independent Lasers[J]. Chinese Journal of Lasers, 2011, 38(4): 408002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Nov. 12, 2010

    Accepted: --

    Published Online: Mar. 24, 2011

    The Author Email: Xuefeng Peng (pexufe@126.com)

    DOI:10.3788/cjl201138.0408002

    Topics