Laser & Optoelectronics Progress, Volume. 62, Issue 1, 0122002(2025)

Design of Strain and Temperature Field Endoscopic Detection System for Hot-End Components of Aircraft

Hao Wang1,2、*, Kun Du1, Zhiming Xie3, Jing Zhu1, and Huijie Huang1
Author Affiliations
  • 1Laboratory of Information Optics and Optoelectronic Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3Shanghai Lasensor Optoelectronics Technology Co., Ltd., Shanghai 201821, China
  • show less
    Figures & Tables(13)
    Schematic diagram of working state of probe
    Schematic diagram of working principle of probe
    Schematic diagram of optimized probe optical system
    Spot diagrams of imaging channels. (a) λ=440 nm; (b) λ=530 nm
    Distortion curve graphs
    MTF curves and relative illuminance curves under different wavelengths. (a)(c) λ=440 nm; (b)(d) λ=530 nm
    Simulated image results at 20 ℃. (a) Test images; (b) λ=440 nm; (c) λ=530 nm
    MTF curves at different temperatures. (a) T′=50 ℃, λ=440 nm; (b) T′=50 ℃, λ=530 nm; (c) T′=150 ℃, λ=440 nm; (d) T′=150 ℃, λ=530 nm; (e) T′=250 ℃, λ=440 nm; (f) T′=250 ℃, λ=530 nm
    • Table 1. Technical parameters

      View table

      Table 1. Technical parameters

      ParameterValue
      Working distance /mm90
      Field of view /(mm×mm)>8×8
      Distortion /%<0.1
      Resolution>0.3(cut-off frequency is 40 lp/mm)
      Wavelength /nm(440±20), (530±20), and (1600±50)
      Optical aperture /mm<10
      Image height (temperature channel) /mm<1
      Image height (imaging channel) /mm>25
    • Table 2. Main optical parameters of imaging channels

      View table

      Table 2. Main optical parameters of imaging channels

      ParameterValue(λ=440 nm)Value(λ=530 nm)
      Working distance /mm8790
      Entrance pupil diameter /mm9.279.89
      Working f-number16.7517.28
      Object space NA0.0440.042
      Image height /mm14.6814.67
      Focal length /mm-62.62-67.77
      Total track /mm828.39819.27
    • Table 3. Main optical parameters of temperature measurement channels

      View table

      Table 3. Main optical parameters of temperature measurement channels

      ParameterValue
      Working distance /mm87
      Entrance pupil diameter /mm9.27
      Working f-number16.75
      Object space NA0.044
      Image height /mm0.8
      Total track /mm816.62
    • Table 4. Tolerance setting

      View table

      Table 4. Tolerance setting

      ToleranceValue
      Aperture3
      Sample toleranceA
      Surface irregularity /fringes0.3
      Thickness /mm±0.05
      Element decenter /mm±0.01
      Tilt /(°)±0.02
      Refractive index0.001
      Abbe number /%1
    • Table 5. Monte Carlo sampling analysis results

      View table

      Table 5. Monte Carlo sampling analysis results

      Sampling ratio /%MTF(λ=440 nm)MTF(λ=530 nm)
      ≥900.300.33
      ≥800.350.37
      ≥500.420.39
      ≥200.470.40
      ≥100.490.41
    Tools

    Get Citation

    Copy Citation Text

    Hao Wang, Kun Du, Zhiming Xie, Jing Zhu, Huijie Huang. Design of Strain and Temperature Field Endoscopic Detection System for Hot-End Components of Aircraft[J]. Laser & Optoelectronics Progress, 2025, 62(1): 0122002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Apr. 11, 2024

    Accepted: Apr. 29, 2024

    Published Online: Jan. 6, 2025

    The Author Email:

    DOI:10.3788/LOP241083

    CSTR:32186.14.LOP241083

    Topics