Chinese Journal of Lasers, Volume. 41, Issue 11, 1108008(2014)

A Self-Calibration Method for Bore-Sight Error of Ground-Based Mobile Mapping System

Meng Xiangang1、*, Hu Shaoxing2, Zhang Aiwu1, Duan Yihao1, and Zhang Xiao1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(13)

    [1] [1] Chen Tian. Data processing methodology for laser measurement point cloud[J]. Laser & Optoelectronics Progress, 2011, 48(9): 091202.

    [3] [3] Shao Jie, Zhang Aiwu, Wang Shumin, et al.. Research on fusion of 3D laser point clouds and CCD image[J]. Chinese J Lasers, 2013, 40(5): 0514001.

    [4] [4] C Glennie, K Kusevic, P Mrstik. Performance analysis of a kinematic terrestrial LiDAR scanning system[C]. MAPPS/ASPRS 2006 Fall Conference, 2006.

    [5] [5] C Glennie. Rigorous 3D error analysis of kinematic scanning LiDAR systems[J]. Journal of Applied Geodesy, 2007, 1(3): 147-157.

    [6] [6] Wang Zhihua, Zhang Aiwu, Wang Shumin, et al.. Airborne radar calibration system based on the overlap strip[J]. Chinese J Lasers, 2014, 41(2): 0214003.

    [7] [7] C Glennie. Reign of point clouds: A kinematic terrestrial lidar scanning system[J]. Inside GNSS, 2007, 2(7): 22-31.

    [8] [8] Yuan Xiuxiao, Yang Fen, Zhao Qing, et al.. Boresight misalignment calibration of integrated D GPS/IMU system[J]. Geomatics and Information Science of Wuhan University, 2006, 31(12): 1039-1043.

    [9] [9] P Rieger, N Studnicka, M Pfennigbauer, et al.. Boresight alignment method for mobile laser scanning systems[J]. Journal of Applied Geodesy, 2010, 4(1): 13-21.

    [10] [10] P Kumari, W E Carter, R L Shrestaha. Adjustment of systematic errors in ALS data through surface matching[J]. Advances in Space Research, 2011, 47(10): 1851-1864.

    [11] [11] E Grafarend, J Awange. Applications of Linear and Nonlinear Models[M]. Berlin: Springer Press, 2012.

    [12] [12] J Skaloud, P Schaer. Towards a more rigorous boresight calibration[C]. ISPRS International Workshop on Theory Technology and Realities of Inertial/GPS/Sensor Orientation, 2003.

    [13] [13] Guan Yunlan, Cheng Xiaojun, Shi Guigang. A robust method for fitting a plane to point clouds[J]. Journal of Tongji University (Natural Science), 2008, 36(7): 981-984.

    Tools

    Get Citation

    Copy Citation Text

    Meng Xiangang, Hu Shaoxing, Zhang Aiwu, Duan Yihao, Zhang Xiao. A Self-Calibration Method for Bore-Sight Error of Ground-Based Mobile Mapping System[J]. Chinese Journal of Lasers, 2014, 41(11): 1108008

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Mar. 19, 2014

    Accepted: --

    Published Online: Oct. 29, 2014

    The Author Email: Xiangang Meng (mxg_gxm@sina.com)

    DOI:10.3788/cjl201441.1108008

    Topics