Journal of Atmospheric and Environmental Optics, Volume. 18, Issue 5, 494(2023)

Calibration of cavity mirror reflectivity in off-axis integrated cavity output spectroscopy based on radio frequency noise sources

TIAN Xing1,2,3, ZHU Lewen2,3, LI Long1,2,3, HUA Zisen1,2,3, CAO Yanan1, and CHENG Gang1、*
Author Affiliations
  • 1State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines,Anhui University of Science and Technology, Huainan 232001, China
  • 2School of Artificial Intelligence, Anhui University of Science and Technology, Huainan 232001, China
  • 3Institute of Artificial Intelligence and Big Data, Anhui University of Science and Technology, Huainan 232001, China
  • show less
    References(19)

    [1] Wilkerson J, Sayres D S, Smith J B et al. In situ observations of stratospheric HCl using three-mirror integrated cavity output spectroscopy[J]. Atmospheric Measurement Techniques, 14, 3597-3613(2021).

    [2] He Q X, Zheng C T, Zheng K Y et al. Off-axis integrated cavity output spectroscopy for real-time methane measurements with an integrated wavelength-tunable light source[J]. Infrared Physics & Technology, 115, 103705(2021).

    [3] Zhou J C, Zhao W X, Zhang Y et al. Amplitude-modulated cavity-enhanced absorption spectroscopy with phase-sensitive detection: A new approach applied to the fast and sensitive detection of NO2[J]. Analytical Chemistry, 94, 3368-3375(2022).

    [4] Reynard L M, Wong W W, Noreen T. Accuracy and practical considerations for doubly labeled water analysis in nutrition studies using a laser-based isotope instrument (off-axis integrated cavity output spectroscopy)[J]. The Journal of Nutrition, 152, 78-85(2022).

    [5] Wang X, Jansen H G, Duin H et al. Measurement of δ18O and δ2H of water and ethanol in wine by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry[J]. European Food Research and Technology, 247, 1899-1912(2021).

    [6] Pal M, Bhattacharya S, Maity A et al. Exploring triple-isotopic signatures of water in human exhaled breath, gastric fluid, and drinking water using integrated cavity output spectroscopy[J]. Analytical Chemistry, 92, 5717-5723(2020).

    [7] Fourel F, Lécuyer C, Jame P et al. Simultaneous δ2H and δ18O analyses of water inclusions in halite with off-axis integrated cavity output spectroscopy[J]. Journal of Mass Spectrometry, 55, e4615(2020).

    [8] Wang D, Xie P H, Hu R Z et al. Progress of measurement of atmospheric NO3 radicals[J]. Journal of Atmospheric and Environmental Optics, 10, 102-116(2015).

    [9] Gupta A, Singh P J, Gaikwad D Y et al. Instrumentation and signal processing for the detection of heavy water using off axis-integrated cavity output spectroscopy technique[J]. Review of Scientific Instruments, 89, 023110(2018).

    [10] Dyroff C. Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy[J]. Optics Letters, 36, 1110(2011).

    [11] Gong Y, Li B, Han Y. Optical feedback cavity ring-down technique for accurate measurement of ultra-high reflectivity[J]. Applied Physics B, 93, 355-360(2008).

    [12] Varma R M, Venables D S, Ruth A A et al. Long optical cavities for open-path monitoring of atmospheric trace gases and aerosol extinction[J]. Applied Optics, 48, B159-B171(2009).

    [13] Washenfelder R A, Langford A O, Fuchs H et al. Measurement of glyoxal using an incoherent broadband cavity enhanced absorption spectrometer[J]. Atmospheric Chemistry and Physics, 8, 7779-7793(2008).

    [14] Tian X, Cao Y, Wang J J et al. High sensitivity detection of two-component CH4/H2O based on of f-axis cavity enhanced absorption spectroscopy[J]. Spectroscopy and Spectral Analysis, 39, 3078-3083(2019).

    [15] Wu L Y, Gao G Z, Liu X et al. Study on the calibration of reflectivity of the cavity mirrors used in cavity enhanced absorption spectroscopy[J]. Spectroscopy and Spectral Analysis, 41, 2945-2949(2021).

    [16] Li Z B, Ma H L, Cao Z S et al. High-sensitive off-axis integrated cavity output spectroscopy and its measurement of ambient CO2 at 2 μm[J]. Acta Physica Sinica, 65, 61-67(2016).

    [17] Mikhailenko S N, Kassi S, Mondelain D et al. A spectroscopic database for water vapor between 5850 and 8340 cm-1[J]. Journal of Quantitative Spectroscopy Radiative Transfer, 179, 198-216(2016).

    [18] Nikitin A V, Lyulin O M, Mikhailenko S N et al. GOSAT-2009 methane spectral line list in the 5550-6236 cm-1 range[J]. Journal of Quantitative Spectroscopy and Radiative Transfer, 111, 2211-2224(2010).

    [19] Qi R B, He S K, Li X T et al. Simulation of TDLAS direct absorption based on HITRAN database[J]. Spectroscopy and Spectral Analysis, 35, 172-177(2015).

    Tools

    Get Citation

    Copy Citation Text

    Xing TIAN, Lewen ZHU, Long LI, Zisen HUA, Yanan CAO, Gang CHENG. Calibration of cavity mirror reflectivity in off-axis integrated cavity output spectroscopy based on radio frequency noise sources[J]. Journal of Atmospheric and Environmental Optics, 2023, 18(5): 494

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 31, 2022

    Accepted: --

    Published Online: Dec. 1, 2023

    The Author Email: Gang CHENG (chgmech@mail.ustc.edu.cn)

    DOI:10.3969/j.issn.1673-6141.2023.05.009

    Topics