Study on Time Delay of Impurity Line Emissions Between in the Edge and Core Plasmas in EAST Tokamak

Da-wei YE*, Fang DING1; *;, Ke-dong LI1; 2;, Xia-hua CHEN1; 2;, Yu LUO1; 2;, Qing ZHANG1; 2;, Ling-yi MENG1; 2;, and Guang-nan LUO1; 2;
Author Affiliations
  • 1. Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • show less
    Figures & Tables(6)
    Geometry of viewing chords for the relevant diagnostics on EASTDiv-W (magenta): divertor visible spectroscopy system viewing the upper outer(UO)tungsten divertor target; EUV (black): extreme ultraviolet spectrometer viewing the core plasma; UO-LP (blue): divertor Langmuir probes at the UO target; UO-GP (green): gas puff inlet at the UO target. A typical separatrix of the main plasma is also shown with the blue line
    Divertor visible spectroscopy system on EAST(a): Schematic diagram of Div-W system; (b): Light path diagram viewing the UO divetor target in EAST vacuum chamber
    Typical spectra measured by divertor visible spectroscopy system
    (a): Temporal evolutions of Ar Ⅱ line emission from the upper divertor (black), Ar ⅩⅥ line emission from the core plasma (red) and the voltage signal of piezo valve for Ar seeding (magenta); (b): Correlation coefficient ρ as a function of shift time between the Ar ⅩⅥ and the Ar Ⅱ signal; The rising time period of the spectral lines [3~4.5 s indicated by the shaded area in Fig.4 (a)] is used to calculate the correlation coefficient
    Time traces of main plasma parameters of discharge #85263 and #85272(a): Plasma current IP; (b): Power of 4.6 GHz LHW (c): Ar Ⅱ line emission detected by Div-W, Ar ⅩⅥ line emission detected by EUV and the voltage signal of piezo valve for Ar seeding in shot #85263; (d): Ar Ⅱ emission detected by Div-W, Ar ⅩⅥ emission detected by EUV and the voltage signal of piezo valve for Ar seeding in shot #85272; (e): Electron temperature (Tet) near the outer strike point of the upper divertor
    (a): The correlation coefficient ρ between the Ar Ⅱ signal and the Ar ⅩⅥ signal as a function of shift time of two typical discharges (#85263 and #85272) with different 4.6 GHz LHW powers; (b): Scatter graph between the maximum correlation coefficient ρ and the corresponding delay time in the similar discharges except for with different 4.6 GHz LHW powers, red for P4.6 GHz=1.5 MW and blue for P4.6 GHz=2.5 MW
    Tools

    Get Citation

    Copy Citation Text

    Da-wei YE, Fang DING, Ke-dong LI, Xia-hua CHEN, Yu LUO, Qing ZHANG, Ling-yi MENG, Guang-nan LUO. Study on Time Delay of Impurity Line Emissions Between in the Edge and Core Plasmas in EAST Tokamak[J]. Spectroscopy and Spectral Analysis, 2022, 42(11): 3507

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Aug. 23, 2021

    Accepted: --

    Published Online: Nov. 23, 2022

    The Author Email: Da-wei YE (dawei.ye@ipp.ac.cn)

    DOI:10.3964/j.issn.1000-0593(2022)11-3507-05

    Topics