Chinese Optics Letters, Volume. 2, Issue 7, 07411(2004)

Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration

Wenliang Chen, Rong Liu, Houxin Cui, Kexin Xu*, and Lina Lv
Author Affiliations
  • State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072
  • show less
    References(10)

    [1] [1] O. S. Khalil, Clinical Chem. 45, 165 (1999).

    [2] [2] Dahne, Claus, Gross, and Daniel, Spectrophotometric method and apparatus for the non-invasive determination of glucose in body tissues US patent 4655225 (April 7, 1987).

    [3] [3] S. F. Malin, T. L. Ruchti, T. B. Blank, S. N. Thennadil, and S. L. Monfre, Clinical Chem. 45, 1651 (1999).

    [4] [4] J. Tenhunen, H. Kopola, and R. Myllyla, Measurement 24, 173 (1998).

    [5] [5] K. Maruo, M. Tsurugi, J. Chin, T. Ota, H. Arimoto, Y. Yamada, M. Tamura, M. Ishii, and Y. Ozaki, IEEE J. Sel. Top. Quantum Electron. 9, 322 (2003).

    [6] [6] K. X. Xu, W. L. Chen, J. Y. Jiang, and Q. J. Qiu, Proc. SPIE 5330, 83 (2004).

    [7] [7] M. A. Arnold, G. W. Small, D. Xiang, J. Qui, and D. W. Murhammer, Anal. Chem. 76, 2583 (2004).

    [8] [8] I. V. Meglinski and S. J. Matcher, Physiol. Meas. 23, 741 (2002).

    [9] [9] W. L. Chen, R. Liu, H. X. Cui, and K. X. Xu, J. Optoelectron. Laser (in Chinese) 15, 242 (2004).

    [10] [10] T. L. Troy and S. N. Thennadil, J. Biomed. Opt. 6, 167 (2001).

    CLP Journals

    [1] Huijuan Tian, Ying Liu, Lijun Wang, Xiaojuan Zhang, Zonghui Gao, "Influence of high-order optical parameters of tissue on spatially resolved reflectance in the region close to the source," Chin. Opt. Lett. 4, 02105 (2006)

    [2] [in Chinese], [in Chinese], [in Chinese]. Study of the Effect of Temperature on Optical Properties of Biological Tissue-simulating Phantom[J]. Acta Optica Sinica, 2007, 27(6): 1080

    [3] [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], "Possible correlation between second-order dispersion and glucose concentration investigated by low time-coherence interferometry," Chin. Opt. Lett. 3, 91 (2005)

    [4] [in Chinese], [in Chinese]. Dependence of Optical Clearing Effect on Tissue Structure[J]. Chinese Journal of Lasers, 2006, 33(7): 998

    [5] [in Chinese], [in Chinese], [in Chinese]. The Study of Non-Destructive Measurement of Fruit Internal Qualities Using Spectral Imaging[J]. Acta Optica Sinica, 2007, 27(11): 2042

    [6] Yue Yang, Wenliang Chen, Zhenzhi Shi, Kexin Xu, "Reference point of floating-reference method for blood glucose sensing," Chin. Opt. Lett. 8, 421 (2010)

    [7] [in Chinese], [in Chinese]. Influence of Permeation Characteristics of Hyperosmotic Agents on Optical Clearing of Gastric Tissue Studied with Near-Infrared Spectroscopy[J]. Chinese Journal of Lasers, 2005, 32(5): 717

    Tools

    Get Citation

    Copy Citation Text

    Wenliang Chen, Rong Liu, Houxin Cui, Kexin Xu, Lina Lv, "Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration," Chin. Opt. Lett. 2, 07411 (2004)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 26, 2004

    Accepted: --

    Published Online: Jun. 6, 2006

    The Author Email: Kexin Xu (kexin@tju.edu.cn)

    DOI:

    Topics