Infrared and Laser Engineering, Volume. 44, Issue 8, 2309(2015)

Middle infrared colorimetric temperature measurement method considered influence of atmosphere and ambient

Lv You1,2, Yang Bo3, Wei Zhonghui1, He Xin1, Chang Songtao1,2, and Sun Zhiyuan1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(18)

    [1] [1] Feng Chi, Zhang Chongguan, Wang Zhaofeng, et al. The wavelength selection of colorimetric temperature measurement [J]. Applied Science and Technology, 2013, 40(3): 45-49.

    [2] [2] Shahla Keyvan,Rodney Rossow, Carlos Romero. Blackbody-based calibration for temperature calculations in the visible and near-IR spectral ranges using a spectrometer[J]. FUEL,2006, 85: 796-802.

    [3] [3] Li Jun, Liu Meidong, Zen Yike, et al. Research on non-contact infrared temperature measurement [J]. Piezoelectrics & Acousto Optics, 2001, 23(3): 202-205.

    [4] [4] Shi Deheng,Dai Qirun, Chen Yuke, et al. Optimal design of a practical dual-wavelength high-precision fiber-optic colorimeter [J]. Chinese Journal of Scientific Instrument, 2005, 26(12): 1238-1243.

    [5] [5] Si Yang. Research of dual-wavelength temperature measurement method based on color image sensor[D]. Xi′an: North University of China, 2013. (in Chinese)

    [7] [7] Sun Yuan, Peng Xiaoqi, Tang Ying. Revised method of temperature measurements using two-color thermometry based on CCD image sensor [J]. Chinese Journal of Scientific Instrument, 2008, 29(1): 49-54.

    [8] [8] Zhu Jianhua. Transient high-temperature measurement based on colorimetric temperature measurement technology for high-energy damage blast field [D]. Xi′an: North University of China, 2011.

    [9] [9] Carlos Romero, Xianchang Li, Shahla Keyvan. Spectrometer-based combustion monitoring for flame stoichiometry and temperature control [J]. Applied Thermal Engineering, 2005, 25: 659-676.

    [10] [10] Feng Wenjing. Research on intermediate infrared colorimetric pyrometry system[D]. Harbin: Harbin Institute of Technology, 2013. (in Chinese)

    [11] [11] Cao Lihua. Correction-based dual-waveband color comparison thermometric method [J]. Chinese Journal of Scientific Instrument, 2012, 33(8): 1882-1888. (in Chinese)

    [12] [12] Xing Jichuan, Liu Guangrong, Jin Weiqi, et al. Dual waveband colorimetric temperature measurement method and analysis [J]. Infrared Technology, 2013, 23(1): 71-75. (in Chinese)

    [13] [13] Ren Y, Zhou X M. Survey of dual waveband colorimetric temperature measurement technology[C]//2014 26th Chinese Control and Decision Conference(CCDC), 2014: 5177-5181.

    [14] [14] Li Yunhong,Ma Rong, Zhang Heng, et al. Dual waveband colori-metric temperature accurate measurement tecnhology [J]. Infrared and Laser Engineering, 2015, 44(1): 27-35. (in Chinese)

    [15] [15] Sun Zhiyuan, Chang Songtao, Zhu Wei. Radiation calibration method for infrared system with large aperture and broad dynamic range[J]. Acta Opticsa Sinica, 2013, 23(1): 0712006-1-0712006-7. (in Chinese)

    [16] [16] Luo Maojie, Zhou Jinmei, Fu Jingneng, et al. Integration time as variable for radiometric calibration of infrared system [J]. Infrared and Laser Engineering, 2013, 42(1): 36-40. (in Chinese)

    [17] [17] Han Qijin, Zhang Xuewen, Qiao Zhiyuan, et al. Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites[J]. Infrared and Laser Engineering, 2015, 44(1): 127-133. (in Chinese)

    Tools

    Get Citation

    Copy Citation Text

    Lv You, Yang Bo, Wei Zhonghui, He Xin, Chang Songtao, Sun Zhiyuan. Middle infrared colorimetric temperature measurement method considered influence of atmosphere and ambient[J]. Infrared and Laser Engineering, 2015, 44(8): 2309

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 红外技术及应用

    Received: Dec. 8, 2014

    Accepted: Jan. 13, 2015

    Published Online: Jan. 26, 2016

    The Author Email:

    DOI:

    CSTR:32186.14.

    Topics