Acta Optica Sinica, Volume. 43, Issue 2, 0211001(2023)

Three-Dimensional Light-Sheet Microscopy Imaging System with Liquid Zoom Lens and Galvanometer Mirror

Hongdi Li1, Hongxia Zhang1、*, Xiaomin Song1, Ruoxin Zhao1, Guoxin Wu2, Dagong Jia1, and Tiegen Liu1
Author Affiliations
  • 1Key Laboratory of Optoelectronic Information Technology, Ministry of Education, Tianjin University, Tianjin 300000, China
  • 2Key Laboratory of Modern Measurement and Control Technology, Ministry of Education, Beijing Information Science & Technology University, Beijing 100192, China
  • show less
    Figures & Tables(13)
    Schematic diagram of 3D light-sheet microscopy imaging system based on liquid zoom lens and galvanometer mirror
    Object-image relationship of double telecentric optical path
    Control principal diagram of optical slice microscopic system
    Images formed by periodic fringe mask and magnification of microscopic imaging system during zooming process of liquid lens. (a) IETL=0 mA; (b) IETL=60 mA; (c) IETL=120 mA; (d) IETL=180 mA; (e) IETL=240 mA; (f) IETL=293 mA; (g) magnification is 9.09
    Relationship between distance of main plane of object and applied current IETL of liquid zoom lens
    Gaussian beam, Gaussian light sheets, and relationship between position of scanning light sheet of scanning galvanometer and applied voltage VG_M. (a) Gaussian beam; (b) Gaussian light sheet; Gaussian light sheets detected by optical beam profilers for (c) VG_M=0 mV, (d) VG_M=50 mV, (e) VG_M=100 mV, (f) VG_M=150 mV, (g) VG_M=200 mV, (h) VG_M=250 mV, (i) VG_M=300 mV, (j) VG_M=350 mV, and (k) VG_M=400 mV; (l) relationship between position of scanning light sheet of scanning galvanometer and applied voltage
    Synchronous scanning relationship between galvanometer mirror and liquid zoom lens. (a) Flow chart for measuring synchronous scanning relationship between galvanometer mirror and liquid zoom lens; (b) corresponding relationship between applied voltage of galvanometer mirror VG_M and current of liquid zoom lens, and corresponding position of main plane of object
    Sequence chart of control signal of synchronous control system
    Imaging results of fluorescent microsphere with diameter of 10 μm. (a) Two-dimensional image distribution of sample; (b) local magnified image of fluorescent microsphere in box in Fig. 9(a) and normalized intensity distribution curve and Gaussian fitting result
    Measurement results of system point spread function. (a) Three-dimensional reconstructed images of fluorescent microsphere sample with diameter of 0.5 μm projected along xy, yz, and xz planes; normalized intensity distributions of point spread function along (b) lateral and (c) axial directions and Gaussian fitting results
    Fluorescent microsphere images at different depth and 3D reconstruction image of fluorescent microsphere sample. (a) z=60 μm; (b) z=150 μm; (c) z=240 μm; (d) z=330 μm; (e) 3D reconstruction of fluorescent microsphere samples by volume rendering algorithm
    Imaging results of zebrafish embryo head at different depth
    Imaging results of zebrafish heart beating process
    Tools

    Get Citation

    Copy Citation Text

    Hongdi Li, Hongxia Zhang, Xiaomin Song, Ruoxin Zhao, Guoxin Wu, Dagong Jia, Tiegen Liu. Three-Dimensional Light-Sheet Microscopy Imaging System with Liquid Zoom Lens and Galvanometer Mirror[J]. Acta Optica Sinica, 2023, 43(2): 0211001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Jun. 7, 2022

    Accepted: Aug. 1, 2022

    Published Online: Feb. 7, 2023

    The Author Email: Zhang Hongxia (hxzhang@tju.edu.cn)

    DOI:10.3788/AOS221275

    Topics