Optics and Precision Engineering, Volume. 19, Issue 9, 2300(2011)

Numerical analysis of GRIN lens based miniature probes for optical coherence tomography

WANG Chi1、*, MAO You-xin2, TANG Zhi1, FANG Chen1, YU Ying-jie1, and QI Bo3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(11)

    [1] [1] HUANG D, SWANSON E A., LIN C P, et al . Optical coherence tomography[J]. Science, 1991, 254(5035):1178-1181.

    [2] [2] YANG Y L, DING ZH H, MENG J, et al.. Common path optical coherence tomographic system suitable for endoscopic imaging[J]. Acta Optica Sinica, 2008,28(5):955-959.

    [3] [3] SWANSON E, PETERSEN C L, MCNAMARA E, et al.. Ultrasmall optical probes, imaging optics, and methods for using same: U.S.6445939[P].2002.

    [4] [4] REED W A, YAN M F, SCHNITZER M J. Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry[J]. Opt. Lett., 2002, 27:1794-1796.

    [5] [5] JAFRI M S, FARHANG S, TANG R S, et al.. Optical coherence tomography in the diagnosis and treatment of neurological disorders[J]. J. Biomed Opt., 2005,10(5):051603.

    [6] [6] LI H, STANDISH B A, MARIAMPILLAI A, et al.. Feasibility of interstitial Doppler optical coherence tomography for in vivo detection of microvascular changes during photodynamic Therapy[J]. Lasers Surgery Med., 2006, 38:754-761.

    [7] [7] MAO Y X,CHANG SH,SHERIF SH, et al.. Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging[J]. Applied Optics, 2007,46(23):5887-5894.

    [8] [8] MAO Y X,CHANG SH,FLUERARU C. Fiber lens for ultra-small probes used in optical coherent tomography[J]. J. Biomedical Science and Engineering, 2010, 3:27-34.

    [9] [9] CHEN X D, WANG Y, LI H F, et al.. Fast Fourier transform analysis of single-detector polarization-sensitive optical coherence tomographic signals[J]. Opt. Precision Eng., 2010, 18(8):1746-1753.(in Chinese)

    [10] [10] LI G, ZHENG Y, LIN L, et al.. Monte Carlo simulation of Fourier-domain OCT in multi-layered media[J]. Opt. Precision Eng., 2008,16(7):1285-1294.(in Chinese).

    [11] [11] KE L, DU Q, SU Z. OCT image denoising method based on multi-scale Wiener filtering[J]. Opt. Precision Eng., 2008,16(4):740-745.(in Chinese).

    CLP Journals

    [1] Wang Chi, Bi Shubo, Ding Wei, Yu Yingjie, Ouyang Hangkong. Optical Characteristic Parameters of Gradient-Index Fiber Probe[J]. Chinese Journal of Lasers, 2012, 39(9): 905001

    [2] Chi WANG, Danyang REN, Jinbo CHEN, Shuaishuai ZHANG, Jianmei SUN. Side-viewing all-fiber lens and its focusing performance for SS-OCT imaging system[J]. Optics and Precision Engineering, 2023, 31(15): 2171

    Tools

    Get Citation

    Copy Citation Text

    WANG Chi, MAO You-xin, TANG Zhi, FANG Chen, YU Ying-jie, QI Bo. Numerical analysis of GRIN lens based miniature probes for optical coherence tomography[J]. Optics and Precision Engineering, 2011, 19(9): 2300

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 8, 2011

    Accepted: --

    Published Online: Oct. 11, 2011

    The Author Email: WANG Chi (wangchi@shu.edu.cn)

    DOI:10.3788/ope.20111909.2300

    Topics