Acta Optica Sinica, Volume. 36, Issue 6, 634001(2016)

Ring Artifacts Correction Method Based on Dynamic Current for Cone Beam CT

Chen Siyu*, Li Lei, Yan Bin, Xi Xiaoqi, Zhang Feng, Han Yu, Zhang Xiang, Deng Lin, and Li Jianxin
Author Affiliations
  • [in Chinese]
  • show less
    References(20)

    [1] [1] Ma Jiming, Zhang Jianqi, Song Guzhou, et al.. Total variation constrained iterative filtered backprojection CT reconstruction method[J]. Acta Optica Sinica, 2015, 35(2): 0234002.

    [2] [2] Kyriakou Y, Prell D, Kalender W A. Ring artifact correction for high-resolution micro CT[J]. Physics in Medicine and Biology, 2009, 54(17): 385-391.

    [3] [3] Anas E M A, Kim J G, Lee S Y, et al.. Comparison of ring artifact removal methods using flat panel detector based CT images[J]. Biomedical Engineering Online, 2011, 10(1): 72.

    [4] [4] Mao Lingtao, Fu-pen Chiang, Yuan Zexun. Three-dimensional displacement measurement in solid using digital volumetric speckle photography based on computer tomography[J]. Acta Optica Sinica, 2015, 35(3): 0312001.

    [5] [5] Seibert J A, Boone J M, Lindfors K K. Flat-field correction technique for digital detectors[C]. SPIE, 1998, 3336: 348-354.

    [6] [6] Zhu Y L, Zhao M L, Li H W, et al.. Micro-CT artifacts reduction based on detector random shifting and fast data inpainting[J]. Medical Physics, 2013, 40(3): 031114.

    [7] [7] Ashrafuzzaman A N M, Lee S Y, Hasan M K. A self-adaptive approach for the detection and correction of stripes in the sinogram: Suppression of ring artifacts in CT imaging[J]. EURASIP Journal on Advances in Signal Processing, 2011: 183547.

    [8] [8] Prell D, Kyriakou Y, Kalender W A. Comparison of ring artifact correction methods for flat-detector CT[J]. Physics in Medicine and Biology, 2009, 54(12): 3881-3895.

    [9] [9] Sijbers J, Postnov A. Reduction of ring artifacts in high resolution micro-CT reconstructions[J]. Physics in Medicine and Biology, 2004, 49(14): 247-254.

    [10] [10] Jha D, Srensen H O, Dobberschütz S, et al.. Adaptive center determination for effective suppression of ring artifacts in tomography images[J]. Applied Physics Letters, 2014, 105(14): 143107.

    [11] [11] Anas E M A, Kim J G, Lee S Y, et al.. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging[J]. Physics in Medicine and Biology, 2011, 56(19): 6495-6519.

    [12] [12] Zhang D H, Ning R L, Chen B, et al.. Accurate and efficient calibration method for a selenium flat-panel-detector-based volume tomographic angiography imaging system[C]. SPIE, 1999, 3659: 626-636.

    [13] [13] Tang X Y, Ning R L, Yu R F, et al.. Cone beam volume CT image artifacts caused by defective cells in X-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm[J]. Medical Physics, 2001, 28(5): 812-825.

    [14] [14] Park C J, Lee H K, Song W Y, et al.. Defective pixel map creation based on wavelet analysis in digital radiography detectors[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011, 634(1): 101-105.

    [15] [15] Altunbas C, Lai C J, Zhong Y C, et al.. Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors[J]. Medical Physics, 2014, 41(9): 091913.

    [16] [16] Blinov N N, Vasil'ev V N, Gromov G D, et al.. Effect of the anode current of an X-ray tube on the intensity and energy spectrum of its radiation[J]. Biomedical Engineering, 1984, 18(3): 96-99.

    [17] [17] Wischmann H A, Luijendijk H A, Meulenbrugge H J, et al.. Correction of amplifier nonlinearity, offset, gain, temporal artifacts, and defects for flat-panel digital imaging devices[C]. SPIE, 2002, 4682: 427-437.

    [18] [18] Chen Jiaoze. Research on characteristics of the photodiode detector in industrial computed tomography[D]. Chongqing: Chongqing University, 2011.

    [19] [19] Nelms D W, Shukla H I, Nixon E, et al.. Assessment of three dead detector correction methods for cone-beam computed tomography[J]. Medical Physics, 2009, 36(10): 4569-4576.

    [20] [20] Zhang Guoqiang, Zhou Hu, He You, et al.. Ring artifacts correction of computerized tomography image based on polar-coordinate transform[J]. Acta Optica Sinica, 2012, 32(5): 0534001.

    CLP Journals

    [1] ZHANG Xiang, YAN Bin, LI Lei, LIAN Jing-dong, XI Xiao-qi, CHEN Si-yu, ZHANG Feng, LI Jian-xin. Multi-current X-ray Projection Fusion Method Based on Dynamic Time Warping[J]. Acta Photonica Sinica, 2017, 46(1): 112002

    Tools

    Get Citation

    Copy Citation Text

    Chen Siyu, Li Lei, Yan Bin, Xi Xiaoqi, Zhang Feng, Han Yu, Zhang Xiang, Deng Lin, Li Jianxin. Ring Artifacts Correction Method Based on Dynamic Current for Cone Beam CT[J]. Acta Optica Sinica, 2016, 36(6): 634001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-Ray Optics

    Received: Jan. 8, 2016

    Accepted: --

    Published Online: Jun. 6, 2016

    The Author Email: Siyu Chen (chensiyuxd@163.com)

    DOI:10.3788/aos201636.0634001

    Topics