Piezoelectrics & Acoustooptics, Volume. 45, Issue 3, 363(2023)

Echo Detection Method for Reducing "Blind Area" of PMUT

WANG Guanghua1,2, ZHANG Yuchao1,2, HU Yimin2,3, MIAO Bin2,3, ZHANG Shiqin1,2, ZHOU Hongyu1,2, ZHAO Xiangyong4, and LI Jiadong1,2,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    References(11)

    [1] [1] QIU Z,LU Y.Review of ultrasonic ranging methods and their current challenges[J].Micromachines,2022,13(4):520.

    [2] [2] ROBICHAUD A,CICEK P,DESLANDES D,et al.Frequency tuning technique of piezoelectric ultrasonic transducers for ranging applications[J].Journal of Microelectromechanical Systems,2018,27(3):570-579.

    [4] [4] YAO Y,JU X,LU J,et al.Acoustic emission and echo signal compensation techniques applied to an ultrasonic logging-while-drilling caliper[J].Sensors,2017,17(6):1351.

    [5] [5] CHANG K.Effects of a parallel resistor on electrical characteristics of a piezoelectric transformer in open-circuit transient state[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,2007,54(1):107-117.

    [6] [6] HERNNDEZ ,URE A J,MAZO M,et al.Reduction of blind zone in ultrasonic transmitter/receiver transducers[J].Sensors & Actuators A Physical,2007,133(1):96-103.

    [8] [8] PRZYBYLA R J,SHELTON S E,GUEDES A,et al.In-air rangefinding with an AlN piezoelectric micromachined ultrasound transducer[J].IEEE Sensors Journal,2011,11(11):2690-2697.

    [9] [9] LIU X,CHEN X,LE X,et al.Reducing ring-down time of PMUTs with phase shift of driving waveform[J].Sensors and Actuators A:Physical,2018,281:100-107.

    [10] [10] WU Z,LIU W,TONG Z,et al.A novel transfer function based ring-down suppression system for PMUTs[J].Sensors,2021,21(19):6414.

    [11] [11] LING J,CHEN Y,CHEN Y,et al.Design and characterization of high-density ultrasonic transducer array[J].IEEE Sensors Journal,2018,18(6):2285-2290.

    [12] [12] ZAMORA I,LEDESMA E,URANGA A,et al.High accuracy ultrasound micro-distance measurements with PMUTs under liquid operation[J].Sensors,2021,21(13):4524.

    [14] [14] DIAGRAMF B,DESCRIPTION G.Fast,voltage-out,DC-440 MHz,95 dB logarithmic amplifier AD8310 [EB/OL].(2013-05-06)[2022-10-18].http://https://www.mendeley.com/catalogue/6f4da273-60ae-3fdc-b56a-733bd997edb6/

    Tools

    Get Citation

    Copy Citation Text

    WANG Guanghua, ZHANG Yuchao, HU Yimin, MIAO Bin, ZHANG Shiqin, ZHOU Hongyu, ZHAO Xiangyong, LI Jiadong. Echo Detection Method for Reducing "Blind Area" of PMUT[J]. Piezoelectrics & Acoustooptics, 2023, 45(3): 363

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 22, 2022

    Accepted: --

    Published Online: Dec. 5, 2023

    The Author Email:

    DOI:10.11977/j.issn.1004-2474.2023.03.009

    Topics