Acta Optica Sinica, Volume. 39, Issue 12, 1228005(2019)
Correction Method for Frame-Transfer Blurring Effect of Spaceborne Polarization Camera
Fig. 1. Two types of frame-transfer blurring effect of DPC. (a) Smear; (b) response difference between upper and lower parts
Fig. 2. Correction procedure of frame-transfer blurring effect for on-orbit imaging data of DPC
Fig. 3. Results of frame-transfer blurring effect corrected by dark line method with correction sequence of smear type first and then response-difference type. (a) Original imaging of integral sphere; (b) correction of smear frame-transfer blurring effect; (c) correction of response-difference frame transfer blurring effect
Fig. 4. Results of frame-transfer blurring effect corrected by dark line method with correction sequence of response-difference type first and then smear type. (a) Correction of response-difference frame-transfer blurring effect; (b) correction of smear frame-transfer blurring effect
Fig. 5. Results of frame-transfer blurring effect corrected by matrix method with correction sequence of smear type first and then response-difference type. (a) Correction of smear frame-transfer blurring effect; (b) correction of response-difference frame transfer blurring effect
Fig. 6. Results of frame-transfer blurring effect corrected by matrix method with correction sequence of response-difference type first and then smear type. (a) Correction of response-difference frame-transfer blurring effect; (b) correction of smear frame-transfer blurring effect
Fig. 7. Correction result of response-difference frame-transfer blurring effect. (a) Imaging mosaic of integral sphere in field-of-view; (b) correction of response-difference frame-transfer blurring effect
Fig. 8. Comparison and verification of correction accuracy of smear frame-transfer blurring effect for unsaturated imaging data. (a) Original smear frame-transfer blurring effect; (b) correction by dark line mothed; (c) correction by matrix method; (d) gray-value curve of line 210 in spot
Fig. 9. Comparison and verification of correction accuracy of smear frame-transfer blurring effect for saturated imaging data. (a) Original smear frame-transfer blurring effect; (b) correction by dark line mothed; (c) correction by matrix mothed; (d) gray-value curve of line 380 beneath spot
Fig. 10. Polarization images before and after correction of frame-transfer blurring effect. (a) Before correction; (b) after correction
Fig. 11. Variation of relative value of polarization degree along orbit before and after correction
|
|
Get Citation
Copy Citation Text
Jianwen Weng, Yinlin Yuan, Xiaobing Zheng, Qing Kang, Bihai Tu, Jianjun Li, Jin Hong. Correction Method for Frame-Transfer Blurring Effect of Spaceborne Polarization Camera[J]. Acta Optica Sinica, 2019, 39(12): 1228005
Category: Remote Sensing and Sensors
Received: Jun. 24, 2019
Accepted: Sep. 2, 2019
Published Online: Dec. 6, 2019
The Author Email: Yuan Yinlin (ylyuan@aiofm.ac.cn)