Chinese Optics, Volume. 16, Issue 2, 466(2023)

Imaging comparison experiment of an underwater imaging system with a semiconductor white laser, a monochromatic laser and an LED white light as the light source

Zi-qi JIANG2, Xiao-mei LIU1、*, Fu-hong CAI1, Dian ZHANG1, Wei-yu CAI1, and Hua LIU1
Author Affiliations
  • 1College of Mechanical and Electrical Engineering, Hainan University, Haikou 570228, China
  • 2Fuzhou Vocational Technical College, Fuzhou 344000, China
  • show less
    Figures & Tables(25)
    Schematic diagram of the underwater laser imaging experiment
    Experimental setup for red, green and blue lasers
    Output spectrum of semiconductor white laser
    Output spectrum of the semiconductor red laser
    Output spectrum of the semiconductor green laser
    Output spectrum of the semiconductor blue laser
    Underwater lighting test with different light sources
    The lighting effect of different light sources illuminating green leaves, safflower and oranges in clear water at a distance of 5 cm from the water surface
    The lighting effect of different light sources illuminating green leaves, safflower and orange targets in clear water at a distance of 19 cm from the water surface
    The lighting effects of different light sources illuminating green leaves, safflower, and oranges in seawater at a distance of 5 cm from the water surface
    The lighting effects of different light sources illuminating green leaves, safflower, and oranges in seawater at a distance of 19 cm from the water surface
    Images of different size templates with the underwater imaging distance of 19 cm processed by median filter method. (a) Original image; (b) gray image; template processing results with (c) 3×3 window size; (d) 5×5 window size; (e) 7×7 window size; (f) 9×9 window size
    Image processing results of the histogram equalization algorithm with an underwater imaging distance of 19 cm
    Original image (left) and processing results (right) of piecewise linear grayscale transformation of underwater imaging at a distance of 19 cm
    Imaging results with different light sources when the underwater imaging distance is 15 cm in clear water and seawater
    Imaging with different light sources near the water surface in clear water and seawater
    Image processing results obtained with the light source LED1 in seawater imaging on the water surface
    Image processing results obtained with the light source LED2 in seawater imaging on the water surface
    Image processing results obtained with the light source white laser in seawater imaging on the water surface
    Image processing and evaluation method
    Image processing results of object A taken near the water surface under different white light sources in seawater
    Image processing results of object B taken near the water surface under different white light sources in seawater
    • Table 1. Relevant optical parameters of the LED white light source

      View table
      View in Article

      Table 1. Relevant optical parameters of the LED white light source

      LED1LED2
      Color temperature/K72615846
      Dominant wavelength/nm477.9518.9
      Color rendering index/Ra6364.9
      R proportion/(%)11.711.8
      G proportion/(%)86.486.2
      B proportion/(%)1.82
    • Table 2. Results of Peak Signal to Noise Ratio (PSNR)

      View table
      View in Article

      Table 2. Results of Peak Signal to Noise Ratio (PSNR)

      LED1 object A/BLED2 object A/Bwhite laser object A/B
      CLAHE12.8346/14.558813.1192/16.535820.1845/20.4774
      Laplacian Pyramid Fusion 18.9785/17.007117.8455/13.035919.0232/18.9562
      F-C12.2237/12.972812.3596/11.964117.0214/17.6895
      C-F12.0095/11.704811.5700/10.876217.1908/16.0493
    • Table 3. Results of Structural Similarity Image Integnity(SSIM)

      View table
      View in Article

      Table 3. Results of Structural Similarity Image Integnity(SSIM)

      LED1 object A/BLED2 object A/Bwhite laser object A/B
      CLAHE0.8416/0.71220.7904/0.87090.8230/0.9070
      Laplacian Pyramid Fusion 0.9279/0.92510.9249/0.92910.9465/0.9398
      F-C0.8088/0.65900.7510/0.80580.7550/0.8749
      C-F0.8271/0.56150.7610/0.73920.7687/0.8184
    Tools

    Get Citation

    Copy Citation Text

    Zi-qi JIANG, Xiao-mei LIU, Fu-hong CAI, Dian ZHANG, Wei-yu CAI, Hua LIU. Imaging comparison experiment of an underwater imaging system with a semiconductor white laser, a monochromatic laser and an LED white light as the light source[J]. Chinese Optics, 2023, 16(2): 466

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Original Article

    Received: Jul. 22, 2022

    Accepted: --

    Published Online: Apr. 4, 2023

    The Author Email: Xiao-mei LIU (liuxm@hainanu.edu.cn)

    DOI:10.37188/CO.EN.2022-0012

    Topics