Chinese Optics, Volume. 17, Issue 3, 580(2024)

A simplified method for high temperature calibration in the visible light band

Yun-long LI*, Zhou LI, Zhi-yuan SUN, and Guo-qing YANG
Author Affiliations
  • Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
  • show less
    Figures & Tables(6)
    Experimental setup of high temperature calibration for RGB camera
    The mean gray values for each channel of camera varying with the exposure time
    The mean gray values for each channel of the camera as a function of the brightness of the blackbody radiation. (a) R channel; (b) G channel; (c) B channel
    • Table 1. The slope and intercept values of each channel of an RGB camera under certain exposure time

      View table
      View in Article

      Table 1. The slope and intercept values of each channel of an RGB camera under certain exposure time

      R通道曝光时间/μsR通道斜率/(DN·W−1·m2·sr)R通道截距/DNG通道曝光时间/μsG通道斜率/(DN·W−1·m2·sr)G通道截距/DNB通道曝光时间/μsB通道斜率/(DN·W−1·m2·sr)B通道截距/DN
      1452.1750.582762.5250.741370.8453.08
      3645.4452.794804.3753.104442.7255.12
      5458.1454.705755.2454.065343.2755.90
    • Table 2. 9 unknowns for simplified calibration

      View table
      View in Article

      Table 2. 9 unknowns for simplified calibration

      $ {K_{\rm{r}}} $(W−1·m2·sr·μs−1$ {B_{\rm{r}}} $ (W−1·m2·sr·μs−1$ G_{\rm{r}}^{\rm{noise}} $(DN)$ {K_{\rm{g}}} $ (W−1·m2·sr·μs−1$ {B_{\rm{g}}} $ (W−1·m2·sr·μs−1$ G_{\rm{g}}^{\rm{noise}} $ (DN)$ {K_{\rm{b}}} $ (W−1·m2·sr·μs−1$ {B_{\rm{b}}} $(W−1·m2·sr·μs−1$ G_{\rm{b}}^{\rm{noise}} $(DN)
      0.01490.010349.070.00910.011247.670.00610.007052.10
    • Table 3. Error between calculated and calibrated values

      View table
      View in Article

      Table 3. Error between calculated and calibrated values

      温度(K)400 μs500 μs
      R(%)G(%)B(%)R(%)G(%)B(%)
      973.15−1.110.43−0.222.17−0.570.73
      1023.150.320.91−0.573.38−0.15−0.40
      1073.15−0.062.561.010.630.381.10
      1123.150.782.48−1.14−1.980.28−0.89
      1173.15−0.052.490.03−2.820.53−0.20
      1223.15−0.181.090.621.15−0.75−0.83
      1273.15--0.230.72--−0.00−0.04
      1323.15----−0.45----−0.03
    Tools

    Get Citation

    Copy Citation Text

    Yun-long LI, Zhou LI, Zhi-yuan SUN, Guo-qing YANG. A simplified method for high temperature calibration in the visible light band[J]. Chinese Optics, 2024, 17(3): 580

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Original Article

    Received: Jul. 21, 2023

    Accepted: Aug. 30, 2023

    Published Online: Jul. 31, 2024

    The Author Email:

    DOI:10.37188/CO.2023-0122

    Topics