Acta Optica Sinica, Volume. 37, Issue 8, 0801003(2017)

Automated Radiation Calibration Method Based on DunhuangRadiometric Calibration Site

Jiayan Lü1, Mingyuan He1, Lin Chen2,3、*, Xiuqing Hu2,3, and Xin Li4
Author Affiliations
  • 1 College of Meteorology and Oceanography, PLA University of Science and Technology,Nanjing, Jiangsu 211101, China
  • 2 National Satellite Meteorological Center, China Meteorological Administration, Beijing 100081, China
  • 3 Key Laboratory of Radiometric Calibration and Validation for Environmental Satellite,China Meteorological Administration, Beijing 100081, China
  • 4 Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • show less
    Figures & Tables(9)
    Flowchart of automated ground data processing
    Influence of different AOD and ATR observed value error on reflectivity error at top of atmosphere
    Difference of equivalent reflectivity between ASD measured data and ATR observed data
    Ground reflectivity of Dunhuang site measured by ASD from the year of 2011 to 2015
    Hyperspectral ground reflectivity fitted by multi-channel reflectivity
    Difference among ISO of different BRDF in MODIS channel 1-7
    • Table 1. Atmospheric parameters and observation geometry parameters at satellite transit time

      View table

      Table 1. Atmospheric parameters and observation geometry parameters at satellite transit time

      DateAODWater vapor density /(g·cm -2 )O 3 content /DUSolar zenith angle /(°)Satellite zenith angle /(°)Relative azimuth angle /(°)
      2015-08-210.1221.0003297.430.0725.62128.47
      2015-09-130.0570.5284298.038.1415.19127.64
      2015-09-200.0580.8644277.241.363.97127.81
      2015-09-290.0571.0058272.144.5915.20126.21
      2015-10-040.0610.5353298.748.7218.66309.70
      2015-10-080.0590.3661302.348.1925.34124.70
      2015-10-130.0590.5836286.751.277.59306.46
      2015-10-220.0600.6129288.354.103.81119.56
      2015-10-270.0610.3299303.857.4628.86307.98
      2015-10-310.0600.9927285.256.6814.83124.73
      2015-11-070.0770.5817317.458.793.61121.88
      2015-11-120.0580.5128301.961.6928.86305.62
      2015-11-250.0540.4370271.262.2725.34119.46
      2015-12-020.0600.2636285.063.7815.01118.64
      2015-12-090.0600.4296288.264.803.79121.79
      2016-01-150.0670.3557322.163.7428.76298.27
      2016-03-070.2390.3822302.946.5614.83118.11
    • Table 2. Relative deviation D , mean relative deviation and standard deviation between Rc and Rm %

      View table

      Table 2. Relative deviation D , mean relative deviation and standard deviation between Rc and Rm %

      DateD
      λ1λ2λ3λ4λ5λ6λ7
      2015-08-21-0.44-1.151.57-0.41-0.25-3.590.09
      2015-09-130.870.990.80-0.84-0.05-2.131.87
      2015-09-200.861.18-0.08-1.07-0.310.192.86
      2015-09-291.312.640.75-1.212.22-0.073.50
      2015-10-040.501.27-1.69-2.25-0.820.642.72
      2015-10-082.702.802.850.633.04-3.422.00
      2015-10-13-0.42-0.08-0.270.29-0.36-2.582.43
      2015-10-22-2.50-0.98-1.74-4.121.350.483.04
      2015-10-270.591.772.51-1.572.92-2.933.57
      2015-10-31-1.200.383.40-3.684.110.743.81
      2015-11-07-2.34-0.13-0.96-4.673.180.214.66
      2015-11-121.433.302.69-0.783.091.705.10
      2015-11-252.504.380.38-2.412.080.666.24
      2015-12-021.972.912.43-0.992.672.400.13
      2015-12-091.373.34-1.18-1.353.410.441.96
      2016-01-152.593.86-0.12-2.043.852.645.68
      2016-03-07-0.28-1.053.241.611.911.033.23
      Mean relative deviation0.561.500.86-1.461.88-0.213.11
      Standard deviation1.581.801.751.651.641.971.70
    • Table 3. Relative deviation of results obtained by automated radiation calibration method and reflectance-based method%

      View table

      Table 3. Relative deviation of results obtained by automated radiation calibration method and reflectance-based method%

      MethodRelative deviation
      λ1λ2λ3λ4λ5λ6λ7
      Automated radiation calibration method-0.44-1.151.57-0.41-0.25-3.590.09
      Reflectance-based method-1.00-1.980.49-0.390.94-0.815.29
    Tools

    Get Citation

    Copy Citation Text

    Jiayan Lü, Mingyuan He, Lin Chen, Xiuqing Hu, Xin Li. Automated Radiation Calibration Method Based on DunhuangRadiometric Calibration Site[J]. Acta Optica Sinica, 2017, 37(8): 0801003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Mar. 8, 2017

    Accepted: --

    Published Online: Sep. 7, 2018

    The Author Email: Chen Lin (chenlin@cma.gov.cn)

    DOI:10.3788/AOS201737.0801003

    Topics