NUCLEAR TECHNIQUES, Volume. 47, Issue 6, 060201(2024)

Optimization analysis of low and medium level radioactive solid waste activity reconstruction voxels

Xuezhi JIANG1, Weiguo GU1, Chenyu SHAN2, Hui YANG1, and Dezhong WANG1、*
Author Affiliations
  • 1Machinery and Power Engineering College, Shanghai Jiaotong University, Shanghai 200240, China
  • 2China Nuclear Power Technology Research Institute Co., Ltd., Shenzhen 518000, China
  • show less
    Figures & Tables(17)
    Schematic diagram of horizontal level measurement of waste drum
    Schematic diagram of circumferential mesh merging(a) Traditional meshing, (b) Circumferential mesh merging and partitioning
    Schematic representation of radial meshing with different exponential weights
    Variations of line source efficiency with radius under different measurement conditions
    Schematic diagram of voxel division optimization method
    Schematic diagram of traditional voxel division(a1) 2×12, (a2) 2×18, (a3) 2×24, (b1) 3×12, (b2) 3×18, (b3) 3×24, (c1) 4×12, (c2) 4×18, (c3) 4×24
    Diagram of random distribution of radioactive sources
    Reconstruction error statistics under bipartite division of voxel radial
    Reconstruction error statistics under voxel radial tripartite division
    Reconstruction error statistics under voxel radial quadripartite division
    Reconstruction error statistics for voxel partition optimization methods
    Diagram of point source distribution at voxel boundary
    Trend diagram of activity reconstruction error with radius variation
    Count rate deviation of different voxel partitions
    • Table 1. Measurement conditions

      View table
      View in Article

      Table 1. Measurement conditions

      测量工况Measuring condition准直器开口Collimator opening size / cm×cm测量位置Detector measurement position / cm
      工况1 Case120×90
      工况2 Case220×96
      工况3 Case320×915
      工况4 Case420×921
      工况5 Case520×927
      工况6 Case610×93
      工况7 Case710×99
      工况8 Case810×912
      工况9 Case910×918
      工况10 Case1010×924
    • Table 2. Reconstruction error statistics after radial voxel division optimization

      View table
      View in Article

      Table 2. Reconstruction error statistics after radial voxel division optimization

      体素划分Voxel partition type最小误差Min / %最大误差Max / %均方根误差RMSE / %
      2×12-79.91260.0788.11
      2×18-75.11268.4389.47
      2×24-72.39271.0890.75
      3×12-51.27149.9646.76
      3×18-46.85145.7443.19
      3×24-49.92130.0940.40
      4×12-38.0281.5329.13
      4×18-23.2383.2624.64
      4×24-20.9491.1422.10
      e=0.5-29.2323.308.01
      e=0.8-7.5824.757.52
      e=1.0-2.3224.928.58
      e=1.5-1.3725.9111.85
    • Table 3. The number of conditions divided by different voxels

      View table
      View in Article

      Table 3. The number of conditions divided by different voxels

      体素划分Voxel partition type条件数 Condition number
      2×182.91×105
      3×184.69×105
      4×124.28×105
      4×181.58×106
      4×241.89×107
    Tools

    Get Citation

    Copy Citation Text

    Xuezhi JIANG, Weiguo GU, Chenyu SHAN, Hui YANG, Dezhong WANG. Optimization analysis of low and medium level radioactive solid waste activity reconstruction voxels[J]. NUCLEAR TECHNIQUES, 2024, 47(6): 060201

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Jun. 10, 2023

    Accepted: --

    Published Online: Jul. 8, 2024

    The Author Email: Dezhong WANG (王德忠)

    DOI:10.11889/j.0253-3219.2024.hjs.47.060201

    Topics