Chinese Optics Letters, Volume. 14, Issue 11, 110605(2016)

High performance fiber optic gyroscope with a radiation-tolerant and temperature-stable scale factor

Yuanhong Yang1,2、* and Fuling Yang1
Author Affiliations
  • 1School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China
  • 2National Key Laboratory on Inertial Technology, Beihang University, Beijing 100191, China
  • show less
    Figures & Tables(10)
    Schematic diagram of the Vπ measurement system.
    Performance tested result of Vπ.
    Relationship of Vπ versus λ at different temperatures.
    Configuration of the experimental IFOG.
    Wavelength shift and SF errors at different temperatures.
    Radiation experiment photograph.
    Tested SF error, mean wavelength and the SF calculated with the tested mean wavelength.
    • Table 1. Model Parameters with Linear Fitting (m=kλλ+mλ0)

      View table
      View in Article

      Table 1. Model Parameters with Linear Fitting (m=kλλ+mλ0)

      T (°C)kλ (V/nm2)mλ0 (V/m)R2
      −40.27.300927×1080.0022210.9991
      −29.77.814259×1080.0022020.9993
      −20.58.766196×1080.0021760.9996
      −9.49.333737×1080.0021560.9992
      0.81.009304×1070.0021330.9995
      10.41.078659×1070.0021100.9996
      20.41.156246×1070.0020870.9994
      29.81.238980×1070.0020630.9997
      40.51.307796×1070.0020410.9993
      50.31.381143×1070.0020180.9995
      60.71.446607×1070.0019960.9994
      70.41.529232×1070.0019730.9993
    • Table 2. Model Parameters with Linear Fitting (m=kTT+mT0)

      View table
      View in Article

      Table 2. Model Parameters with Linear Fitting (m=kTT+mT0)

      λ (nm)kT (V/(nm·°C))mT0 (V/m)R2
      1528.3821.1515618×1060.00228680.9993
      1533.4621.1477535×1060.00228730.9997
      1538.5851.1439462×1060.00228780.9994
      1543.3421.1404391×1060.00228830.9996
      1548.5131.1366294×1060.00228880.9995
      1553.3411.1331159×1060.00228930.9997
      1558.5861.1293042×1060.00228980.9998
      1563.4521.1258004×1060.00229030.9995
      1567.9531.1225748×1060.00229080.9992
    • Table 3. SF Error Due to m Dispersion

      View table
      View in Article

      Table 3. SF Error Due to m Dispersion

      λ (nm)1548.4291548.4681548.5131548.5541548.591
      SF error (ppm)4.4682.2630.3122.2324.473
    Tools

    Get Citation

    Copy Citation Text

    Yuanhong Yang, Fuling Yang, "High performance fiber optic gyroscope with a radiation-tolerant and temperature-stable scale factor," Chin. Opt. Lett. 14, 110605 (2016)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Jul. 14, 2016

    Accepted: Sep. 23, 2016

    Published Online: Aug. 2, 2018

    The Author Email: Yuanhong Yang (yhyang@buaa.edu.cn)

    DOI:10.3788/COL201614.110605

    Topics