Chinese Journal of Lasers, Volume. 45, Issue 11, 1110003(2018)

Optical Fiber Temperature Sensor Based on Surface Plasmon Resonance

Yong Wei1、*, Jiangxi Hu1, Zongda Zhu2, Lu Liu3, and Feng Peng4、*
Author Affiliations
  • 1 Chongqing Municipal Key Laboratory of Intelligent Information Processing and Control of Institutions of Higher Education, Chongqing Three Gorges University, Chongqing 404100, China
  • 2 School of Aeronautics, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
  • 3 School of Science, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
  • 4 School of Physics and Technology, University of Jinan, Jinan, Shandong 250022, China
  • show less
    Figures & Tables(9)
    Structural diagram of temperature sensing probe
    SPR transmission spectra under different conditions. (a) Different fiber polishing angles; (b) different gold film thicknesses
    Simulation results of resonance wavelength versus temperature (Inset: transmission spectra under different temperatures)
    Test system of temperature sensing
    Experimental results of resonance wavelength versus temperature (Inset: transmission spectra under different temperatures)
    FWHM of SPR dip and figure of merit versus temperature
    • Table 1. Physical parameters of gold film

      View table

      Table 1. Physical parameters of gold film

      ParameterValue
      ωp0 /(rad·s-1)1.3754×1016
      γe /(℃-1)1.42×10-5
      TD /(℃)-103
      EF /(eV)5.53
      ω0 /(rad·s-1)2.0477×1013
      Γ0.55
      Δ0.77
    • Table 2. Stability test and error analysis

      View table

      Table 2. Stability test and error analysis

      Actual temperature /℃203040506070
      Average of resonance wavelength /nm922.49877.36851.89810.86790.53764.38
      Standard deviation of resonance wavelength /nm0.260.240.330.230.290.30
      Average of calculated temperature /℃19.831.438.751.959.671.2
      Standard deviation of calculated temperature /℃0.060.070.100.080.120.14
      Temperature error /℃-0.21.4-1.31.9-0.41.2
    • Table 3. Sensitivity comparison among different types of optical fiber temperature sensors

      View table

      Table 3. Sensitivity comparison among different types of optical fiber temperature sensors

      TypesSensitivity /(nm·℃-1)Detection range /℃
      FBG[1]0.04230~120
      LPFG[3]0.7720~100
      OFI[6]0.11530~400
      WGM[7]0.37725~45
      SPR[13]2.6020~60
      Proposed4.1520~70
    Tools

    Get Citation

    Copy Citation Text

    Yong Wei, Jiangxi Hu, Zongda Zhu, Lu Liu, Feng Peng. Optical Fiber Temperature Sensor Based on Surface Plasmon Resonance[J]. Chinese Journal of Lasers, 2018, 45(11): 1110003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: remote sensing and sensor

    Received: May. 25, 2018

    Accepted: Jun. 26, 2018

    Published Online: May. 9, 2019

    The Author Email:

    DOI:10.3788/CJL201845.1110003

    Topics