Laser & Optoelectronics Progress, Volume. 61, Issue 4, 0422001(2024)

Error Calibration Method of Null Correctors for Large-Aperture Aspherical Mirrors

Qiuyun Xu* and Lingchen Kong
Author Affiliations
  • School of Photoelectric Engineering, Changzhou Institute of Technology, Changzhou 213032, Jiangsu, China
  • show less
    Figures & Tables(13)
    Pattern distribution of CGH
    Optical layout of the calibration of Offner null using CGH
    The optical layout of concave hyperboloid mirror by Offner compensator
    Ray tracing schematic diagram
    The image quality of calibration path. (a) Spot diagram; (b) wavefront function
    CGH phase function and spatial frequency distribution
    Optical layout of the alignment hologram
    Alignment hologram patterns (line width magnified by 200 times )
    Calibration experiment of Offner compensator
    Calibration result of the Offner compensator
    The Φ856 mm concave hyperboloid mirror and its surface measured by the calibrated Offner compensator
    • Table 1. Coefficients of even polynomials

      View table

      Table 1. Coefficients of even polynomials

      A1A2A3A4A5A6A7A8
      -5.19×1015.27×10-3-1.99×10-61.09×10-9-6.38×10-133.09×10-16-9.79×10-201.43×10-23
    • Table 2. Substrate shape error (λ = 0.6328 μm)

      View table

      Table 2. Substrate shape error (λ = 0.6328 μm)

      IndexWith powerWithout power
      PV0.15λ0.083λ
      RMS0.029λ0.013λ
    Tools

    Get Citation

    Copy Citation Text

    Qiuyun Xu, Lingchen Kong. Error Calibration Method of Null Correctors for Large-Aperture Aspherical Mirrors[J]. Laser & Optoelectronics Progress, 2024, 61(4): 0422001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Sep. 8, 2023

    Accepted: Nov. 14, 2023

    Published Online: Feb. 26, 2024

    The Author Email: Qiuyun Xu (xuqy@czu.cn)

    DOI:10.3788/LOP232075

    CSTR:32186.14.LOP232075

    Topics