Laser & Optoelectronics Progress, Volume. 56, Issue 13, 132301(2019)

Discomfort Glare Caused by R/G/B/W Four-Color Light Emitting Diode Sources

Huijuan Tian1,3、*, Tiantian Hao2,3, Tao Guan1,3, Yang Hu2,3, Minpeng Cai1,3, and Hui Zhang1,3
Author Affiliations
  • 1 Tianjin Key Laboratory of Advanced Electrical Energy Technology, School of Electrical Engineering and Automation, Tianjin Polytechnic University, Tianjin 300387, China
  • 2 School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China
  • 3 Engineering Research Center of High Power Solid State Lighting Application System, Ministry of Education, Tianjin 300387, China
  • show less
    Figures & Tables(13)
    Parameters of unified glare rating RUGR
    Experimental platform. (a) Experimental photo; (b) diagram of experimental setup
    Relative spectral power distributions of R/G/B/W LED modules
    Principle of driving circuit for R/G/B/W LED source modules
    Four-color LED source modules. (a) W-LED; (b) R-LED; (c) G-LED; (d) B-LED
    Relationship between luminance and subjective evaluations of experimental results of four LED glare sources in three different background luminances. (a) W-LED; (b) R-LED; (c) G-LED; (d) B-LED
    Relationship between luminance and subjective evaluations of experimental results of four LED glare sources after linear interpolation in three different background luminances. (a) Lb=45.833 cd·m-2; (b) Lb=19.967 cd·m-2; (c) Lb=11.750 cd·m-2
    Relationship between RUGR value and subjective evaluations of experimental results for four LED glare sources. (a) W-LED; (b) R-LED; (c) G-LED; (d) B-LED
    • Table 1. Discomfort glare evaluated using RUGR

      View table

      Table 1. Discomfort glare evaluated using RUGR

      RUGRDiscomfort glare criterion
      10Imperceptible
      13Just perceptible
      16Perceptible
      19Just acceptable
      22Unacceptable
      25Just uncomfortable
      28Uncomfortable
      31Just intolerable
      34Intolerable
    • Table 2. Parameters of R/G/B/W LED modules in experiment

      View table

      Table 2. Parameters of R/G/B/W LED modules in experiment

      LEDxyLuminous flux /lmPower /W
      W-LED0.3040.312407.1604.356
      R-LED0.6860.314209.0604.157
      G-LED0.1690.687224.7805.445
      B-LED0.1510.03153.0623.710
    • Table 3. Experimental conditions

      View table

      Table 3. Experimental conditions

      ItemLight source
      W-LEDR-LEDG-LEDB-LED
      Luminance level10
      Background luminance /(cd·m-2)45.833, 19.967, 11.750
      Observer10
      Total number of ratings1200
    • Table 4. Luminances of four LED sources at different luminance levels

      View table

      Table 4. Luminances of four LED sources at different luminance levels

      LuminancelevelW-LED /(cd·m-2)R-LED /(cd·m-2)G-LED /(cd·m-2)B-LED /(cd·m-2)
      1380.760250.720350.22034.268
      2823.280514.820739.50072.082
      31242.600768.1001115.400108.060
      41684.4001026.1601507.600146.120
      52100.2001271.4001869.000183.680
      62543.2001520.4002260.800222.140
      72958.6001753.8002628.600258.080
      83409.0001985.8003035.400295.120
      93852.4002207.4003425.400334.460
      104335.0002438.0003839.400342.800
    • Table 5. Glare rating scale

      View table

      Table 5. Glare rating scale

      CategorySemantic criteriaDescription of reaction glare
      1ImperceptibleI am not aware of anything
      2Just perceptibleI am aware there is something but cannot tell what it is
      3NoticeableI am aware of the presence of the luminaire but it does not bother me
      4Just uncomfortableI am aware of a luminaire and I wish it was not there
      5UncomfortableI am aware of a luminaire and I would complain to my supervisor about it
      6Just intolerableI am aware of a luminaire, and if somebody does notdo something about it, I will take direct action myself
      7IntolerableI am aware of a luminaire and I will not stay here a moment longerif somebody does not do something about it, now
    Tools

    Get Citation

    Copy Citation Text

    Huijuan Tian, Tiantian Hao, Tao Guan, Yang Hu, Minpeng Cai, Hui Zhang. Discomfort Glare Caused by R/G/B/W Four-Color Light Emitting Diode Sources[J]. Laser & Optoelectronics Progress, 2019, 56(13): 132301

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Jan. 9, 2019

    Accepted: Jan. 30, 2019

    Published Online: Jul. 11, 2019

    The Author Email: Tian Huijuan (tianhjgx@126.com)

    DOI:10.3788/LOP56.132301

    Topics