Optics and Precision Engineering, Volume. 17, Issue 9, 2159(2009)

Data process of spectroscopic surface plasmon resonance analyzer based on noise analysis

HAO Peng1,2、* and WU Yi-hui1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(11)

    [1] [1] HOMOLA J. Surface plasmon resonance sensors for detection of chemical and biological species [J]. Chem. Rev.,2008,108(2):462-493.

    [2] [2] HOMOLA J. Surface Plasmon Resonance Based Sensors[M]. Germany:Springer,2006.

    [3] [3] HOMOLA J,DOSTALEK J,SHENGFU CH,et al.. Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk[J].Int. J. Food Microbiol.,2002,75:61-69.

    [4] [4] WARK A,HYE J,CORN R. Long-range surface plasmon resonance imaging for bio-affinity sensors [J].Anal. Chem.,2005,77:3904-3907.

    [5] [5] TAKUO A,SATOSHI S,KAZUNORI I,et al.. Refractive-index and thickness sensitivity in surface plasmon resonance spectroscopy [J].Applied Optics,1999,38(19):4058-4064.

    [6] [6] NENNINGER G,PILIARIK M,HOMOLA J. Data analysis for optical sensors based on spectroscopy of surface plasmon[J]. Meas. Sci. Technol.,2002,13 :2038-2046.

    [8] [8] ZYBIN A,BOECKER D,MIPSKY V,et al.. Enhancement of the detection power of surface plasmon resonance measurements by optimization of the reflection angle [J]. Anal. Chem.,2007,79:4233-4236.

    [9] [9] TONG SH F,RUAN J,HAO ZH H. Noise reducing scheme on output signal of CCD[J]. Opt. Precision Eng.,2000,8(2):140-145.(in Chinese)

    [10] [10] http://www.aigproducts.com/surface plasmon resonance/spr curve analysis.html.

    [11] [11] THIRSTRUP C,ZONG W. Data analysis for surface plasmon resonance sensors using dynamic baseline algorithm[J].Sens. Actuat. B Chem.,2005,106:796-802

    CLP Journals

    [1] HUANG Qiang, WANG Min, LI Ang, HAN Xi-da, HE Yong-hong. Symmetrical long range surface plasmon resonance sensing system[J]. Optics and Precision Engineering, 2014, 22(1): 44

    [2] WANG Yi-jia, ZHANG Chong-lei, WANG rong, ZHU Si-wei, YUAN Xiao-cong. Optimization and validation of differential interferometric surface plasmon resonance sensor[J]. Optics and Precision Engineering, 2013, 21(3): 672

    [3] LIU Jin, CHEN Bao-xue, YANG Hai-ma. Ion-exchange single-mode stripe waveguide for excitation of surface plasma wave[J]. Optics and Precision Engineering, 2011, 19(10): 2342

    Tools

    Get Citation

    Copy Citation Text

    HAO Peng, WU Yi-hui. Data process of spectroscopic surface plasmon resonance analyzer based on noise analysis[J]. Optics and Precision Engineering, 2009, 17(9): 2159

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 26, 2008

    Accepted: --

    Published Online: Oct. 28, 2009

    The Author Email: HAO Peng (hp312@126.com)

    DOI:

    CSTR:32186.14.

    Topics