High Power Laser and Particle Beams, Volume. 34, Issue 12, 124002(2022)
Design and beam dynamic analysis of 270° achromatic deflection magnet system
[1] [1] Li Jinhai. Principles key technologies of radio frequency accelerats f electron irradiation[M]. Shanghai: Shanghai Jiao Tong University Press, 2020
[2] [2] Clel M R. Industrial applications of electron accelerats[R]. Zeegse, The herls: CERN Accelerat School, 2006: 383416.
[3] [3] Amano Y. Atoms in industry: radiation technology suppts development[NOL]. Vienna: IAEA Bulletin, 2015. https:www.iaea.gpublicationsmagazinesbulletin563.
[4] [4] Hamm R W. Review of industrial accelerats their applications[R]. APIA12, 2009.
[5] Shahzad A A, Patil B J, Pethe S N, et al. Design of electron beam bending magnet system for electron and photon therapy: a simulation approach[J]. Indian Journal of Pure & Applied Physics, 57, 492-497(2019).
[6] [6] Akhter S, Bhaskar V N, Dhole S D. 270° electron beam bending system using two sect mags f therapy application[C]Proceeding of IBIC 2012. 2012: 5053.
[7] Yang Shaozhou, Yang Guang, Shen Qinxian, . The beam bend magnet system of medical electron accelerator[J]. Chinese Journal of medical Physics, 17, 129-131,133(2000).
[8] Liu Naiquan. Beam transport characteristics of the 270° doubly achromatic bending magnet[J]. Chinese Journal of Nuclear Science and Engineering, 3, 79-89(1983).
[9] Chen Wanzhong, Ji Dongze, Cheng Xige. Development of 270° beam deflection system[J]. Medical Equipment, 22, 46-48(2009).
[10] Li Quanfeng, Kong Chaocheng, Guo Bingqi, . Calculation of the beam loss in the 270° bending magnet system of the medical accelerator[J]. High Energy Physics and Nuclear Physics, 31, 787-791(2007).
[11] [11] Chemerisov S D, Gromov R, Bailey J L, et al. Beamline design beam diagnostic f Mo99 production facility utilizing high power electron accelerats[R]. Argonne: Argonne National Lab, 2019.
[12] Shahzad A, Phatangare A B, Bharud V D, et al. Design and development of the 6-18 MeV electron beam system for medical and other applications[J]. Radiation Effects and Defects in Solids, 172, 931-951(2017).
[13] [13] Brown K L, Turnbull W G. Achromatic magic beam deflection system: 3867635[P]. 19750218.
[14] Hutcheon R M, Heighway E A. A new compact doubly achromatic asymmetric two-magnet beam deflection system[J]. Nuclear Instruments and Methods in Physics Research, 187, 81-87(1981).
[15] [15] Jongen Y, Abs M, Zaremba S, et al. Realignment of a diverging electron beam: a new beam delivery system f Rhodotrons[C]Proceedings of 1997 Particle Accelerat Conference. Vancouver: IEEE, 1997: 38573859.
[16] Li Quanfeng, Zhou Yun. Physical design of a 270° double achromatic bending magnet[J]. Atomic Energy Science and Technology, 29, 423-427(1995).
[17] [17] Michael B. User’s Manual f elegant[EBOL]. Michael Bl: Advanced Photon Source, 2016. https:www3.aps.anl.govfumselegant.
[18] [18] M B, Makino K. COSY INFINITY 9.1 programmer’s manual[EBOL]. East Lansing: Michigan State University, 2011. http:cosyinfinity.g.
[19] [19] Wei Kaiyu. ged beam transpt they[M]. Beijing: Science Press, 1986
Get Citation
Copy Citation Text
Jia Li, Quantang Zhao, Zhaohui Ran, Yuanming Long, Yang Zong, Yulun Li, Shuchun Cao, Xiaokang Shen, Zimin Zhang, Ping Yuan. Design and beam dynamic analysis of 270° achromatic deflection magnet system[J]. High Power Laser and Particle Beams, 2022, 34(12): 124002
Category: Particle Beams and Accelerator Technology
Received: Jun. 2, 2022
Accepted: Aug. 12, 2022
Published Online: Nov. 10, 2022
The Author Email: Zhao Quantang (zhaoquantang@impcas.ac.cn)