    Space uniformity theory. (a) Conversion of reference dimensions; (b) measurement of spatial uniformity
    Light mixing principle of three-light source module
    Structure of plant cultivation rack. (a) Plant culture rack structure; (b) plant culture rack section view; (c) plant culture rack section view and related parameters
    Structure of light source module 3
    S/N values corresponding to each factor level. (a) Illumination uniformity; (b) color-mixed uniformity
    Relationship of lighting quality and H. (a) Illumination uniformity; (b) color-mixed uniformity
    Final optimized results of culture rack on different sampling surfaces. Horizontal sampling plane (a) illuminance distribution; (b) light quality distribution; (c) chromaticity diagram; vertical sampling plane; (d) illuminance distribution; (e) light quality distribution; (f) chromaticity diagram
    Shape of LED chip. (a) I1; (b) I2; (c) I3; (d) I4; (e) I5
    Relationship between lighting quality and LED chip shape. (a) Illumination uniformity; (b) color-mixed uniformity
    Relationship between lighting quality and LED lamp bead spacing. (a) Illumination uniformity; (b) color-mixed uniformity
    Plant growth simulation test model
    Relationship between plant height and light source lighting quality. (a) Illumination uniformity; (b) color-mixed uniformity
    Physical test model
    • Table 1. Influencing factors and standards of plant cultivation racks

      View table

      Table 1. Influencing factors and standards of plant cultivation racks

      CodeFactorNumber of levelsLevel 1Level 2Level 3Level 4
      Ah40.250.500.751.00
      Bs /mm412.525.037.550.0
      CH /mm4200300400500
    • Table 2. Experimental design parameters using L16(45) orthogonal table

      View table

      Table 2. Experimental design parameters using L16(45) orthogonal table

      SerialNo.ABCPlaneIlluminationuniformity /%Color-mixeduniformity /%S/N ofilluminationuniformityS/N ofcolor-mixeduniformity
      1111J89.66489.61638.85639.047
      V51.30790.52934.20339.135
      2122J93.47986.41539.41438.712
      V81.12881.63438.18338.237
      3133J94.52882.22139.51138.299
      V89.88790.24639.07339.108
      4144J92.56185.54739.32938.644
      V90.78085.13539.16038.602
      5212J91.88990.00039.26539.085
      V84.70585.09138.55838.597
      6221J89.51187.77539.03738.864
      V81.14686.98938.18538.789
      7234J94.24786.14839.48538.704
      V95.10987.51739.56438.841
      8243J90.88488.45739.16938.935
      V92.91788.41439.36238.930
      9313J89.20185.53839.00738.643
      V88.05288.65838.89538.954
      10324J93.03987.94739.37338.884
      V92.98389.99939.36839.084
      11331J91.62988.24239.24138.913
      V84.26583.35038.51338.418
      12342J92.17688.22139.29238.911
      V92.35781.41639.30938.214
      13414J92.14287.44939.28938.835
      V89.29586.28139.01638.718
      14423J91.66581.69439.24438.244
      V92.66786.43339.33838.733
      15432J91.64280.66239.24138.133
      V88.56688.07138.94538.897
      16441J91.54387.54639.23238.845
      V88.76984.27138.96538.513
    • Table 3. Contribution rate of each factor to illumination uniformity

      View table

      Table 3. Contribution rate of each factor to illumination uniformity

      CodeHorizontal plane /%Vertical plane /%
      A11.7228.22
      B46.0329.18
      C43.1142.59
    • Table 4. Contribution rate of each factor to color-mixed uniformity

      View table

      Table 4. Contribution rate of each factor to color-mixed uniformity

      CodeHorizontal plane /%Vertical plane /%
      A34.735.54
      B35.1929.96
      C30.0764.49
    • Table 5. Comparison of physical test results and simulation results

      View table

      Table 5. Comparison of physical test results and simulation results

      ConditionPlanePhysical test resultSimulation result
      Illumination uniformity /%J87.3891.35
      V84.0989.71
      Color-mixed uniformity /%J86.2687.67
      V86.8988.54
    Tools

    Get Citation

    Copy Citation Text

    Bo Zhang, Shangsheng Wen, Bingxu Ma, Feiyu Jiao, Yunle Lu, Weizhao Huang. Design of Plant Light Source System Based on Multi-Light Source Module[J]. Acta Optica Sinica, 2020, 40(19): 1923001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Apr. 24, 2020

    Accepted: Jun. 12, 2020

    Published Online: Sep. 27, 2020

    The Author Email: Wen Shangsheng (shshwen@scut.edu.cn)

    DOI:10.3788/AOS202040.1923001

    Topics