Spectroscopy and Spectral Analysis, Volume. 41, Issue 10, 3256(2021)

Research on Gas Concentration Measurement Method Based on Gradient Descent Method to Fit Spectral Absorption Signal Directly

Figures & Tables(8)
Fitting flowchart
Experimental system diagram
Point selection for initial value calculation of incident laser intensity parameters
Convergence speed of five step factors
Fitting results at different concentrations(a): 10%; (b): 12%; (c): 14%; (d): 16%; (e): 18%; (f): 20%
Absorbance at different concentrations obtained by routine baseline fitting
  • Table 1. Spectral parameters of two absorption lines of CO2 around 1 580 nm (296 K)

    View table
    View in Article

    Table 1. Spectral parameters of two absorption lines of CO2 around 1 580 nm (296 K)

    LineWavelength
    /nm
    Linestrength S
    [cm-1·(molecule·cm-2)-1]
    Self-broadening
    γself/(cm-1·atm-1)
    Air-broadening
    γair/(cm-1·atm-1)
    Line11 580.512 71.301×10-230.0960.071 6
    Line21 580.039 51.431×10-230.0980.072 7
  • Table 2. Analyze the results of direct fitting method and integral area method

    View table
    View in Article

    Table 2. Analyze the results of direct fitting method and integral area method

    实际浓度直接拟合法拟合浓度相对误差1拟合方差积分面积法计算浓度相对误差2
    10%10.37%3.70%9.27×10-59.07%-9.30%
    12%12.53%4.40%3.29×10-511.49%-4.25%
    14%14.57%4.07%6.39×10-512.96%-7.43%
    16%16.14%0.90%1.85×10-515.29%-4.44%
    18%17.70%-1.65%8.32×10-517.11%-4.94%
    20%19.79%-1.03%6.92×10-519.18%-4.10%
Tools

Get Citation

Copy Citation Text

. Research on Gas Concentration Measurement Method Based on Gradient Descent Method to Fit Spectral Absorption Signal Directly[J]. Spectroscopy and Spectral Analysis, 2021, 41(10): 3256

Download Citation

EndNote(RIS)BibTexPlain Text
Save article for my favorites
Paper Information

Category: Research Articles

Received: Oct. 10, 2020

Accepted: --

Published Online: Oct. 29, 2021

The Author Email:

DOI:10.3964/j.issn.1000-0593(2021)10-3256-06

Topics