Infrared and Laser Engineering, Volume. 53, Issue 12, 20240426(2024)

Research on vacuum ultraviolet spectral responsivity calibration device based on synchrotron radiation

Hao YANG1, Chunlian ZHAN1, Guangwei SUN2, Zhouhong ZHU1、*, Jiapeng WANG2, Jidong DU2, Guoao ZHOU2, and Kui JIANG2
Author Affiliations
  • 1College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310018, China
  • 2Beijing Zhenxing Institute of Metrology and Testing, Beijing 100074, China
  • show less
    References(15)

    [1] GENG Yongyou, DENG Changmeng, WU Yiqun. Recent progress of extreme ultraviolet resists[J]. Infrared and Laser Engineering, 43, 1850-1856(2014).

    [2] SUN Shiya, Huang Fuxiang, Xia Xueqi.. Forward simulation of solar backscattered ultraviolet radiation for satellite over the Tibetan plateau[J]. Optical Precision Engineering, 30, 256-263(2022).

    [3] ZHANG Yufeng, WANG Hongjie, ZHU Yonghong et al. Research on mars camera[J]. Infrared and Laser Engineering, 45, 209-215(2016).

    [4] LI Han, SUN Hongsheng, WANG Jiapeng et al. Calibration device for UV radiation celestial body simulator[J]. Infrared and Laser Engineering, 43, 1568-1573(2014).

    [5] [5] Xiong Limin, Lin Yong, Fan, Qiming, et al. Research onm easurement methods f spectral responsivity of photodetects in the UV b (200400 nm) [C]Proceedings of the Academic Symposium on Radiation Metrology by the Chinese Society f Metrology Testing, 2006, 2006: 241246.

    [6] CHEN Yinghang, SUI Zuoning, SUN Hongsheng et al. Facility for calibration of ultraviolet and vacuumultraviolet spectral irradiance[J]. Infrared and Laser Engineering, 42, 998-1002(2013).

    [8] ZHAN Chunlian, LI Yanmei, LIU Jianping et al. The unitormity and linearity of infrared spectral response of detector[J]. Journal of Applied Optics, 25, 34-37(2004).

    [10] QUAN Zhike, GAO Yesheng, WANG Hengfei. The measurement for the photo-detector's absolute spectral responsivity based on the cryogenic radiometer[J]. Journal of Astronautic Metrology and Measurement, 29, 70-72(2009).

    [11] WANG Ji, Zheng Xiaobing, Zhang Lei, . et al. Measurement of spectral responsivity of an infrared detector[J]. Journal of Applied Optics, 28, 313-316(2007).

    [12] SUN Gangwei, DU Jidong, LI Shiwei et al. Calibration device for key parameters of VUV detector[J]. Journal of Astronautic Metrology and Measurement, 42, 23-28(2022).

    [13] BÜERMANN L, GROSSWENDT B. Measurement of thex-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation[J]. Physics inMedicine & Biology, 51, 5125(2006).

    [14] SUN Hongsheng, SUN Guangwei, WANG Jiapeng. et al. Research on calibration technology for UV-vacuum ultraviolet imaging spectrometer[J]. Journal of Applied Optics, 778-785(2020).

    [15] LIU Jinyuan, XUE, Fengyi, LI Ping et al. Detector calibration facility in the wavelength range of VUV soft X-Ray(5-105 nm)[J]. Acta Metrologica Sinica, 275-279(2008).

    Tools

    Get Citation

    Copy Citation Text

    Hao YANG, Chunlian ZHAN, Guangwei SUN, Zhouhong ZHU, Jiapeng WANG, Jidong DU, Guoao ZHOU, Kui JIANG. Research on vacuum ultraviolet spectral responsivity calibration device based on synchrotron radiation[J]. Infrared and Laser Engineering, 2024, 53(12): 20240426

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 光电测量

    Received: Sep. 21, 2024

    Accepted: --

    Published Online: Jan. 16, 2025

    The Author Email: Zhouhong ZHU (181615904@qq.com)

    DOI:10.3788/IRLA20240426

    Topics