Acta Optica Sinica, Volume. 44, Issue 3, 0312004(2024)
Luminous Intensity of Plane Light Source Based on Near-Field Distributed Photometry
[1] Yu A Q, Ju J Q, Chen D H. Discussion on the advantages of LED in functional lighting[J]. China Light & Lighting, 10-17(2018).
[2] Hu H Y, Guo Z J, Li Q. Full-field goniophotometer system for LED road lights[J]. China Illuminating Engineering Journal, 20, 59-61(2009).
[3] Hou Q Z, Ma B Z. Near-field intensity detection of LED array based on error feedback[J]. Acta Metrologica Sinica, 42, 993-999(2021).
[4] Gui L, Yin S Y, Cai W T et al. Measurement method of LED etendue based on near-field source model[J]. Acta Photonica Sinica, 46, 0112004(2017).
[5] Rykowski R F, Wooley C B. Source modeling for illumination design[J]. Proceedings of SPIE, 3130, 204-208(1997).
[7] Ashdown I. Comparing photometric distributions[J]. Journal of the Illuminating Engineering Society, 29, 25-33(2000).
[8] Bizjak G, Lindemann M, Sperling A et al. Determination of stray light at the PTB goniophotometer facility[J]. MAPAN, 24, 163-173(2009).
[10] López M, Bredemeier K, Rohrbeck N et al. LED near-field goniophotometer at PTB[J]. Metrologia, 49, S141-S145(2012).
[11] Schmähling F, Wübbeler G, Lopez M et al. Virtual experiment for near-field goniophotometric measurements[J]. Applied Optics, 53, 1481-1487(2014).
[12] Rotscholl I, Trampert K, Krüger U et al. Spectral near field data of LED systems for optical simulations[J]. Proceedings of SPIE, 11144, 111440P(2019).
[13] Gassmann F, Krueger U, Bergen T et al. Comparison of luminous intensity distributions[J]. Lighting Research & Technology, 49, 62-83(2017).
[14] TechnoTeam Bildverarbeitung GmbH. General specification: model series 1400, 1500, 1800, 2000[R]. http://light-all.com/Writable/Resource/product/TT/Specification_RiGO801_1400_1500_1800_2000_eng-signed.pdf.(2015).
[15] Radiant Vision Systems. ProSource software[R]. https://www.radiantvisionsystems.com/sites/default/files/library-documents/Radiant_SPEC_ProSource_EN.pdf.(2020).
[16] Radiant Vision Systems. SIG-400: source imaging goniometer[R]. https://www.radiantvisionsystems.com/sites/default/files/library-documents/Radiant_SPEC_SIG-400-Source-Imaging-Goniometer_EN.pdf.(2022).
[18] Csuti P, Szabó F, Dubnicka R. Comparison of luminous intensity distributions measured on luminaire turning and mirror goniophotometer[C](2016).
[19] Audenaert J, Acuña R P C, Hanselaer P et al. Practical limitations of near-field goniophotometer measurements imposed by a dynamic range mismatch[J]. Optics Express, 23, 2240-2251(2015).
[20] Jin Y H. Study on photometric measurement technology of near-field distribution[D](2017).
[21] Li X N, Chen C, Lü J et al. Measurement technology and application analysis of near-field photometry[J]. China Light & Lighting, 28-32(2018).
[22] Yang J Q. Design and build of near-field goniophotometer based on CA2000[D](2016).
[23] Hu B. Comparative analysis of far-field and near-field distribution photometric testing systems[D](2019).
[24] Ashdown I, Salsbury M. A near-field goniospectroradiometer for LED measurements[C], TuD5(2006).
[25] Fan H Z, Cao M, Li S Z et al. Application and investigation of near-field goniophotometer measurements in LED optical design[J]. Acta Optica Sinica, 32, 1222001(2012).
[26] Bergen A. A practical method of comparing luminous intensity distributions[J]. Lighting Research & Technology, 44, 27-36(2012).
Get Citation
Copy Citation Text
Shaojie Hu, Hongyuan Wang, Zehao He, Qiaofen Zhu, Liangcai Cao. Luminous Intensity of Plane Light Source Based on Near-Field Distributed Photometry[J]. Acta Optica Sinica, 2024, 44(3): 0312004
Category: Instrumentation, Measurement and Metrology
Received: Sep. 18, 2023
Accepted: Nov. 27, 2023
Published Online: Feb. 27, 2024
The Author Email: Cao Liangcai (clc@tsinghua.edu.cn)
CSTR:32393.14.AOS231565