Chinese Journal of Lasers, Volume. 49, Issue 20, 2007208(2022)
Photoacoustic Imaging Technology in Biomedical Imaging
Fig. 1. Principle and main modes of PA imaging[3]. (a) Principle of PA imaging; (b) schematic diagram of PAM; (c) schematic diagram of PACT; (d) schematic diagram of PAE
Fig. 2. Embodiments of different arrayed ultrasound transducers for PACT. (a) PACT system based on planar array ultrasound transducer for PA imaging of mouse brain[6]; (b) PACT system based on cylindrical array ultrasound transducer for PA imaging of breast[11]; (c) PACT system based on spherical array ultrasonic transducer for PA imaging of hand[12]
Fig. 3. Embodiment of PACT based on LED[16]. (a) Schematic of probe with imaging plane and illumination source; (b) PA and US imaging of skin and vasculature
Fig. 4. Embodiment of deep learning for PA imaging[34]. (a) Architecture of Y-NET; (b) in-vitro results of chicken breast phantom
Fig. 6. Embodiments of extended depth-of-field technology in PAM. (a) Diagram of virtual detector concept in SAFT and original and 2D SAFT PA imaging of leaf vein[45]; (b) numerical simulation and experimental measurement of parameter of Bessel beam and PA imaging of zebrafish based on Gaussian beam and Bessel beam illumination[47]
Fig. 11. Embodiments of dual-modality PAE. (a) Schematic diagram of imaging probe of PA-US endoscope and PA-US imaging of rat rectum; (b) schematic diagram of all-optical PA-OCT intravascular probe and PA-OCT imaging of vascular phantom[87]; (c) schematic diagram of imaging probe of PA-HSI endscope and PA-HSI imaging of rabbit rectum in vivo[90]; (d) schematic diagram of imaging probe of PA-PE endscope and US-PA-PE imaging of aorta[91]
Fig. 12. PA molecular imaging in NIR region. (a) Absorption coefficient spectra of endogenous tissue chromophores at their typical concentrations in human body[110]; (b) reduced scattering coefficients of different biological tissues and of intralipid scattering tissue phantom as function of wavelength in 400-1700 nm region, which covers visible, NIR-I, and NIR-II windows[110]; (c) MPE as function of excitation wavelength[110]; (d) PA imaging of mice tumor with 680 nm and 950 nm[113]; (e) PA-US imaging of mice tumor with 1064 nm[112]; (f) PA-US imaging of mice tumor with 1280 nm[111]
Fig. 13. Embodiment of contrast-enhanced PA molecular imaging[116]. (a) Synthesis process of prepared AgBr@PLGA NCs and schematic illustration that tumor area is graphically fixed via redox reaction; (b) PA imaging of mice injected AgBr@PLGA+GSH and graphene
Fig. 14. Embodiment of ratiometric PA molecular imaging[118]. (a) Design and synthesis of quantitative PA diagnosis of gastric and intestinal diseases; (b) US imaging and PA imaging at 790 nm, PA imaging at 1200 nm, and ratiometric PA molecular imaging of stomach
Fig. 15. Embodiment of highly specific activatable probes[120]. (a) Schematic diagram of photoconversion process; (b) cartoon illustration of background-suppressed PA molecular imaging; (c) PA molecular imaging of chicken breast tissue
Fig. 16. Embodiment of probe for integration of diagnosis and treatment[127]. (a) Schematic illustration of NIR-II fluorescence/PA dual-modality imaging guiding tumor targeted combination therapy; (b) FI of Hela-tumor-bearing mice; (c) PA imaging of Hela-tumor-bearing mice; (d) tumor growth profiles of different groups of mice
|
Get Citation
Copy Citation Text
Gen Mu, Zhenhui Zhang, Yujiao Shi. Photoacoustic Imaging Technology in Biomedical Imaging[J]. Chinese Journal of Lasers, 2022, 49(20): 2007208
Category: Biomedical Optical Imaging
Received: Jun. 8, 2022
Accepted: Jul. 19, 2022
Published Online: Oct. 14, 2022
The Author Email: Shi Yujiao (shiyuj@scnu.edu.cn)