Acta Optica Sinica, Volume. 44, Issue 21, 2112001(2024)
Analysis of Factors Influencing Accuracy in Line-Structured Light Three-Dimensional Surface Measurement Systems
Fig. 1. Structural diagram of non-Sham structured line-structured light vision sensor
Fig. 3. System architectures based on translation scanning. (a) Translation scanning structure of moving sensor; (b) translation scanning structure of moving object
Fig. 6. Illustrations of point cloud stitching through rotation scanning. (a) Space point rotation coordinate transformation; (b) point cloud splicing based on rotation scanning
Fig. 9. Impact of uneven brightness of light strip on extraction error of light strip center. (a) Light strip image with uneven brightness; (b) extraction errors of light strip centers with different grayscales
Fig. 10. Assessment experimental results for straightness of light beams from different types of lasers. (a) Line fitting residual of light stripe center of laser 1; (b) line fitting residual of light stripe center of laser 2
Fig. 11. Requirements for laser linewidth from sizes of protrusions and indentations. (a) Requirements for laser linewidths from sizes of protrusions; (b) requirements for laser linewidths from sizes of indentations
Fig. 15. Geometric relationship between center of image light strip and its corresponding point in object space
Fig. 16. Influences of width of light strip W and angle between object and image plane Δφ0 on measurement error of three-dimensional coordinate of center of light strip
Fig. 17. Schematic diagrams of key parameter selection for rotary table. (a) Angle resolution and angle positioning error; (b) end face swing angle and end face runout error
Fig. 19. Schematic diagram of relationship between key characteristics of components and system performance
Fig. 20. Line-structured light scanning measurement system and physical image of its calibration experimental platform
Fig. 22. Three-dimensional point clouds of gauge blocks and standard ball. (a) Three-dimensional point clouds of gauge blocks; (b) three-dimensional point cloud of standard ball
Fig. 24. Results of 3D reconstruction experiments of typical objects. (a) PCB; (b) M6 screw
Get Citation
Copy Citation Text
Tianyu Li, Changwen Liu, Fajie Duan, Xiao Fu, Guangyue Niu, Chunjiang Liang. Analysis of Factors Influencing Accuracy in Line-Structured Light Three-Dimensional Surface Measurement Systems[J]. Acta Optica Sinica, 2024, 44(21): 2112001
Category: Instrumentation, Measurement and Metrology
Received: May. 24, 2024
Accepted: Jun. 19, 2024
Published Online: Nov. 20, 2024
The Author Email: Duan Fajie (fjduan@tju.edu.cn)
CSTR:32393.14.AOS241065