Chinese Journal of Lasers, Volume. 50, Issue 23, 2304004(2023)

Influence of Sample Absorption on Multi-Wavelength High-Order Harmonic Wavefront Reconstruction

Bo Mei1,2 and Zhinan Zeng1,3、*
Author Affiliations
  • 1State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3Zhangjiang Laboratory, Shanghai 200120, China
  • show less
    Figures & Tables(8)
    Simulation sample
    Initial spectral distribution
    Multi-wavelength high-order harmonics reconstruction results. (a) Comparison of amplitude reconstruction; (b) comparison of phase reconstruction; (c) MSE in case of priori sample and without updating; (d) comparison of phase reconstruction in case of simultaneous reconstruction of sample and probe
    Reconstruction results of multi-wavelength high-order harmonics with complex wavefront. (a) Initial spectral distribution; (b) comparison of amplitude reconstruction; (c) comparison of phase reconstruction; (d) MSE during iterative process
    Amplitude reconstruction for each order. (a) 27.6 nm; (b) 31.5 nm; (c) 34.6 nm; (d) 38.1 nm
    Amplitude and phase reconstruction comparison for 34.6 nm harmonic with different sample contrasts. (a) Amplitude reconstruction with sample contrast of 1; (b) amplitude reconstruction with sample contrast of 0.14; (c) amplitude reconstruction with sample contrast of 0.19; (d) amplitude reconstruction with sample contrast of 0.28; (e) phase reconstruction for each order with sample contrast of 0.28
    Influence of sample contrast with 5×5 scan matrix. (a) Amplitude reconstruction for each order with sample contrast of 1; (b) phase reconstruction for each order with sample contrast of 1; (c) amplitude reconstruction for each order with sample contrast of 0.19; (d) phase reconstruction for each order with sample contrast of 0.19
    • Table 1. Comparison of spectral distribution reconstruction

      View table

      Table 1. Comparison of spectral distribution reconstruction

      Wavelengthλ /nmTrue intensity value aSimulated intensity value bDeviationδ /%
      27.60.10830.10900.6464
      29.10.43330.4295-0.8770
      31.50.10830.11041.9391
      34.60.10830.1068-1.3850
      38.10.24180.24441.0753
    Tools

    Get Citation

    Copy Citation Text

    Bo Mei, Zhinan Zeng. Influence of Sample Absorption on Multi-Wavelength High-Order Harmonic Wavefront Reconstruction[J]. Chinese Journal of Lasers, 2023, 50(23): 2304004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Measurement and metrology

    Received: Apr. 13, 2023

    Accepted: May. 9, 2023

    Published Online: Dec. 7, 2023

    The Author Email: Zeng Zhinan (zhinan_zeng@mail.siom.ac.cn)

    DOI:10.3788/CJL230720